Skip to Main Content
Autodesk
ADD A NEW IDEA

Operational Modeling

Showing 8 of 1170

Distribution Network Energy Optimization

Minimize the pumping costs of water distribution while satisfying water demand and operational constraints (water levels, pressure, pump station capacities, future maintenance operations, etc).
Nathan Gerdts 3 months ago in InfoWater Pro / Operational Modeling 0 Gathering support

Provide option to allow for several multipliers and use with selection sets

In addition to a global multiplier, sometimes you want to peak certain areas and selection sets with specific peaking factors. WaterCAD allows for this under their calculation options.
Michele Marston 3 months ago in InfoWater Pro / Operational Modeling 0 Gathering support

VSP Control based on Tank Head/Level

Currently you can only use Junction Pressure setpoints or Pump Flow setpoints in the VSP Control dialogue. It would be helpful to be able to use a Tank Level/Head setpoint to adjust the pump speed as well. This is possible in competitor products l...
Grant Clemens over 1 year ago in InfoWater Pro / Operational Modeling 3 Under consideration

Group InfoWater Pro pumps into a pump station object that aggregates results

As a modeler I want to summarize the behavior of a pump station of multiple pumps using a polygon. This helps me summarize energy usage and total flow without needing to select arbirary upstream or downstream objects. This also helps simplify syst...
Guest almost 3 years ago in InfoWater Pro / Operational Modeling 1 Gathering support

Initial Tank Levels

It would be great to be able to change the initial tank levels without having to create a whole new tank data set or putting a duplicate tank in the current data set. That way, the initial tank level condition can be changed for any given scenario...
Guest almost 5 years ago in InfoWater Pro / Operational Modeling 4 Will not implement

Isolation Scenario Using Dummy Valves Which Do Not Split Pipes

Can you put a valve on top of a pipe (not splitting the pipe) and then it closes the section? And then anything enclosed to these multiple valves will be isolated? This is going to be useful for modelling of isolation scenarios
Guest 10 months ago in InfoWater Pro / Operational Modeling 3 Gathering support

Adjust VSP "Control Value" during model run with Basic Controls

Seems like a fundamental control to be able to adjust a pump's target flow rate dynamically, for a high/low flow setpoint based on tank levels or other triggers. I can currently adjust the speed setting in basic rules, but trying to hit a target f...
Guest over 1 year ago in InfoWater Pro / Operational Modeling 1 Gathering support

Customize pipe ID field in UDF field journal

Currently the model ID's are populated in the "Pipes to Flush" box of the UDF field journal. We store our GIS Asset ID in an information field. We want to use this field as the basis of communication with field teams.
Guest about 4 years ago in InfoWater Pro / Operational Modeling 0 Gathering support