By default display ID in alphabetical order in Control Center Overview in InfoWater Pro

By default display ID in alphabetical order in Control Center Overview in InfoWater Pro
Mickey Liu 4 days ago in InfoWater Pro 0 For Review

Could we add a preference to disable the popup to accept the most recent run data?

The popup is confusing, and we don't see a point in not accepting the latest run results.
Deb Smith 11 days ago in InfoWater Pro / Productivity 2 Gathering support

Provide Velocity Constraint in Multi-Fireflow

Provide the ability to limit velocity for the multi-fireflow run option. Presently only the Fireflow run option offers a max velocity constraint capability; the Multi-Fireflow run option does not have a max velocity feature.
Guest about 1 month ago in InfoWater Pro / Engine 0 Under consideration

Default tank symbol

Can you change the default tank symbol color back to the dark blue that it used to be? The teal color is very light, making it difficult to see and hard to differentiate from the reservoir symbol. I know I can change this in preferences, but it wo...
Colin Ricks 21 days ago in InfoWater Pro / Productivity 0 For Review

Consistent names and icons

Use the same name for things everywhere. For example, in the Model Explorer there is a "Modeling" section. In the DB editor, the field listed in the "Modeling" section are found in the "Hydraulic data" tables. Icons are also often different in dif...
Colin Ricks 21 days ago in InfoWater Pro / Productivity 0 For Review

Easily transform node from one type to another

Self explanatory. Use a user selection or domain.
Colin Ricks 21 days ago in InfoWater Pro / Productivity 0 For Review

"Initially Closed" and "Check Valve Direction" symbology should adhere to the "show inactive elements" toggle

This is simple enough to do by adding a definition query on the MOTYPE field in conjunction with the existing DSPCODE filter, but currently I would have to manually change this for 4 layers every time I toggle display of inactive elements.
Eric King about 1 month ago in InfoWater Pro / Other 1 Under consideration

Totalizer Valve and Controls

It would be very useful to have a totalizer valve which closes after a certain amount of flow passes through over a given time, such as 5 MGD over a day, then reopens once that time period has passed. Alternatively, a control option based on a pip...
Guest 2 months ago in InfoWater Pro / Operational Modeling 1 Under consideration

Pressure Relief Valve

Which valve, if any, would represent a pressure relief valve? Where the pressure on the upstream is not allowed to exceed a certain psi. If it exceeds the specified pressure on the upstream side the valve will open.
Guest about 2 months ago in InfoWater Pro / Operational Modeling 1 For Review

Hydrant Available vs. Hydrant Design

Has anyone had issues with the hydrant available flow being less than the hydrant design flow? It has always been my impression that the hydrant available flow has less constraints and therefore would have a higher fire flow than that of the hydra...
Guest 3 months ago in InfoWater Pro / Automation 1 For Review