Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Other

Showing 12 of 1369

Remove calculations from Notes field

Could Storage Compensation & Numerical Correction calculations be detailed and exported in a separate file (spreadsheet for ease of filtering? possibly date stamped and recording model name, version, path etc) rather than being appended to the...
Giorgio Incelli about 2 years ago in InfoWorks ICM / Other 0 Gathering support

Update RTC to Allow User to Create Folders

It would be very useful to have folders as an option in RTC Editor - this would allow users to group assets based on similar characteristics e.g. type, location, purpose. It would also be useful to be able to change the order of regulators in the ...
David Beesley over 1 year ago in InfoWorks ICM / Other 0 Gathering support

add an AI assistant

This could be at benefit more in the future as this technology gets better, when we would ask to perform certain repetitive tasks. Untill the AI will take our modelling jobs :). But for the moment would be nice to at least quickly querry the bot o...
Ionut Pintea almost 2 years ago in InfoWorks ICM / Other 1 Gathering support

Units for catchment area: add km²

The choice of display units of the catchment area (under Tools--> Options--> Units) is now limited to ha or acre, which is not convenient for our river subcatchments. It would be useful to add the possibility of km².
Michael Huybrighs about 2 years ago in InfoWorks ICM / Other 0 Gathering support

Ability to toggle on and off if 'user defined properties' automatically open when opening an objects properties

I am currently in the process of digitising old IAS plans within ICM. Every time I click on an object to assign it a system and surface within the User Defined Properties, I have to click the + symbol to open the properties. This has to be a very ...
Patrick Fox over 1 year ago in InfoWorks ICM / Other 7 Already exists

Allow user to set number format in ICM grid windows

It would be great if a user could set number formats in InfoWorks ICM grid windows. For example, we are calibrating a large diameter pipeline by adjusting Manning's n values. We are using 5 digits after the decimal place, but ICM only shows 4 digi...
Andrew Fugal almost 5 years ago in InfoWorks ICM / Other 1 Gathering support

Infiltration surface in InfoWorks ICM

Within a part/selection of conduits, I want to know what the (infiltration) surface area is below a certain level (m AD). For example, what is the surface area of the ditch (bottom and sidewalls) up to a level of e.g., 4.0 or 5.0 m AD. Using Model...
Guest almost 2 years ago in InfoWorks ICM / Other 0 Gathering support

On behave of Chinese users, could developing team transfer drainage design module from infoSwmm into ICM?

On behave of Chinese users, could developing team transfer drainage design module from infoSwmm into ICM? Clients in China do have this wish to do drainage and model in same software. Many of our potential client choose Hongye (a simple drainage ...
Guest over 5 years ago in InfoWorks ICM / Other 0 Gathering support

Infoworks ICM - XPSWMM

Provide a easy model/network transport option from one program to the other. Many municipalities within WA utilise XPSWMM and therefore are note able to read an ICM model.
Guest over 5 years ago in InfoWorks ICM / Other 0 Gathering support

Reintroduce ICM 11 searching for a viewer licence if a full licence isn't available

We use ICM version 7, 9 and 11 as per client requirements. We have 2 full licences and 2 viewer licences. When the full licences were already in use, ICM version 7 and 9 would automatically open with a viewer licence. This doesn't happen anymore w...
Tom Newman over 4 years ago in InfoWorks ICM / Other 0 Gathering support