Extra Results Outputs for some features in ICM

Hi there - Doing some work for a client I found the following limitations in results exports from Infoworks ICM: 2D Base Linear Structure: ls_underflow and ls_overflow results variables cannot have a summary of peak value exported by CSV or SHP. T...
Guest 1 day ago in InfoWorks ICM / Results 0 For Review

Display PRN file results in user units

It would be great to see results of a PRN file using the user defined units rather than just native metric units.
Karen Chu 14 days ago in InfoWorks ICM / Results 1 For Review

Expand gauged object results to all result fields

Currently the gauged object result fields are limited. For instance, they do not include 2d related results at nodes. As the use case for ICM has expanded so has the information that users are interested in. No longer as they just looked at 'flow ...
Alex Grist 7 months ago in InfoWorks ICM / Results 2 For Review

In-sewer water temperature model

In-sewer water temperature monitoring has been around for a while. It is useful for identifying groundwater infiltration, potential heat recovery locations, optimising chemical dosing, predicting H2S build up and other key sewer processes. A dynam...
John Ward 4 months ago in InfoWorks ICM / Simulations 2 For Review

Display critical results for indvidual elements

With the variability of design rainfall patterns, critical hydraulic results (mean/median/min/max) often occur at different rainfall durations for different elements (eg specific pipe/MH/channel/etc) within a network for the same rainfall event pr...
matthew.piggott 5 months ago in InfoWorks ICM / Results 1 For Review

Improve database and results files read performance

When opening an ICM network for the first time (i.e. no network files in the local files "Working" folder), the WDS reads through the database file in 4 kB chunks to retrieve the requested version of the network. This read process appears to be li...
Peter Dunlop over 3 years ago in InfoWorks ICM / Performance / Results 3 Gathering support

Partially complete a simulation and review results and then opt to continue the simulation

Simulations often take a long time to run. I would like to be able to "pause" the simulation and review the results to check that the initialisation is correct, or that an RTC is working properly, and if I am happy then continue the simulation to ...
Ann Pugh over 5 years ago in InfoWorks ICM / Productivity / Reporting / Results / Simulations 2 Under consideration

Cross section result view: keyboard shortcuts to go upstream or downstream

In the cross section result view (showing the water level), in RS there was the possibility to go upstream or downstream with PageUp/PageDwn, in ICM you have to right click to move upstream or downstream
Guest about 2 years ago in InfoWorks ICM / Productivity / Results / River Modeling 0 Gathering support

Support for more than two simulations in long sections

When evaluating the effects of raising and lowering roughness it would be helpful to display three or more simulations in the same long section; at the moment it is only possible to display 2.
Richard Body over 5 years ago in InfoWorks ICM / Long Section / Profile / Productivity / Results 0 Gathering support

Export run results to csv: timestep options

When exporting run results to csv, it would be useful to select a timeframe you wish to export (excluding for instance the initial conditions that haven't settled into a level that makes sense). Also exporting at a different timestep than the one ...
Guest about 2 years ago in InfoWorks ICM / Export Data / Results 0 Gathering support