Project Prioritization: Include multiple asset types in a single project

Currently, the Project Prioritization tool can only be run on Gravity Mains or Pressurized Mains separately. It'd be great if the tool could create projects after looking at Gravity Main AND Pressurized Main information or any other asset types. B...
Guest over 6 years ago in Other Product Ideas / Asset Management 0 For Review

Urban (or modified) ReFH rainfall inputs

ICM currently supports the use of ReFH And ReFH2 parameters. However, it does not support the Urban (or modified) ReFH rainfall that is more commonly used in urban environments. Please could ICM introduce the ability to use Urban ReFH parameters i...
Guest almost 5 years ago in InfoWorks ICM / Rainfall 0 Gathering support

Use edit flag for selection of fields only

By using the Use edit flag option, all changed fields are now set to the edit flag. For a lot of fields (for example the us and ds node or the suffix) it is not necessary to set this flag to the Edit flag.
Guest over 6 years ago in InfoWorks ICM / Flags 0 Gathering support

In some types of elements the result of the simulation between consecutive time step are very different (oscillations).

Simulation results very differents between consecutive calculation times in series or cascade regulation elements; such as, pressure regulating valves (PRV), float valves (FLV), pumps, ...
Juan Carlos Ortega over 3 years ago in InfoWorks WS Pro / Engine 2 Already exists

Zoom to domain when inactive facilities selected

When inactive facilities are included in the domain, clicking the "Zoom domain" button only zooms to the extent of the active facilities in the domain. If only inactive facilities are part of the domain (no active facilities at all), then this but...
Colin Ricks over 3 years ago in InfoWater Pro / Productivity 0 Gathering support

Improvement on the Numerical Correction Process in ICM

The current procedure for ‘Numerical Correction’ in ICM requires users to remove any existing values to calculate the correction (for Preismann and Base flow) before the inbuilt routine is run. If this wasn't made the calculated correction values ...
Guest over 6 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

Export to PACP, LACP and MACP v6, v7 and v8 compliant databases

Export v6 and v7 inspections to MDB format Export v8 inspections to SQLite format The exported databases must be NASSCO data exchange standard compliant. The export should support single and batch export of inspections to the NASSCO database forma...
Tony Andrews over 1 year ago in Info360 Asset 0 Will not implement

Show value range or distribution of values when a user is creating a rehab query

Currently, when building a rehab query, a user must guess what a reasonable value is when inputing values in their rehab queries (for anything none choice list). It would be really useful for them to be able to see the range of values or a histogr...
Mike Maylone over 3 years ago in Info360 Asset 0 Under consideration

Populate Pump run schedule based on telemetry data in WS Pro

As a planning modeler calibrating within WS Pro, I want to use the "Load from Live Data" tool on pumps in Plan mode to populate the Control Data timeseries profile based on a data stream of 1's and 0's indicating on/off. While this is already avai...
Guest almost 5 years ago in InfoWorks WS Pro / Telemetry 0 Gathering support

Specify number of demands

I almost never need to use all 10 demand fields in InfoWater. The ability to specify the number of demand fields needed would save space in the demand DB table and in the Model Explorer window and make viewing these windows easier.
Colin Ricks over 6 years ago in InfoWater Pro / Other 3 Under consideration