Velocity Result for Swale Stormwater Control Feature

The velocity parameter in a swale is an important consideration with respect to determining erosion possibility, potential swale lining requirements and help inform check-dam design & locations. As it stands you cannot get the velocity result ...
Shane Moynihan about 1 month ago in InfoDrainage / Hydraulics 0 For Review

Chezy Formula option

It would be useful to have a direct input for Chezy coefficient as an alternative to mannings n as some regions need to use this as an input and report on this too - this would result in less workaround and data manipulation
matthew.piggott 4 days ago in InfoDrainage / Hydraulics 0 For Review

Adding Babbit Formula

Requesting addition of Babbit formula peak factor calculation to Infodrainage program, providing comprehensive analysis for efficient and accurate design and decision-making since Babbit formula peak factor calculation method used in many standard...
Mohamad Azzam 8 months ago in InfoDrainage / Hydraulics 2 Under consideration

Add ability to see all pipes in Network Design Report

It is not possible to view the details / preliminary results of all the connections in the Network Design Report (each flow path needs to be selected in turn). This can be awkward for large networks.
Matthew Johnson about 1 month ago in InfoDrainage / Auditing / Reviewing 0 For Review

Changes to a network do not propagate downstream

If you change a pipe diameter or gradient, it will not accommodate these changes in the downstream section of the network. For example upsizing and steepening a pipe in the middle of a run will mean the next pipeis undersized and goes uphill. It a...
Matthew Johnson about 1 month ago in InfoDrainage / Hydraulics 0 For Review

Calculating and adding the Froude number to storm table output

Many municipalities and utilities want to maintain subcritical flow in the storm sewer system and avoid hydraulic jumps. The Froude number is used to establish subcritical vs. supercritical flow.
Guest 22 days ago in InfoDrainage / Reporting 1 For Review

Export non-connected catchment objects

Currently Civil 3D will not export a catchment object unless is connect to a structure/junction. It should export all catchment objects regardless of if they are connected to a structure/junction.
Guest 22 days ago in InfoDrainage / Hydrology 0 For Review

Canadian Rainfall Data - Built-in Design Storms

Environment Canada has regional rainfall data that should be available automatically in InfoDrainage similar to the NOAA Design Storms currently available in the Rainfall/Pollutants Tab of the software. This is a pain point for Canadian users, as ...
Guest 10 months ago in InfoDrainage / Rainfall 1 Under consideration

Auto-Profile Feature in InfoDrainage

We are asking for a Gravity Auto Profile feature in the InfoDrainage with integration with other services as sanitary, water and electrical …etc. This feature would automate the creation of longitudinal profiles for gravity-fed drainage systems (M...
Mohamad Azzam 8 months ago in InfoDrainage / Hydraulics 3 Gathering support

Ability to move labels to avoid overlaps

At the moment if labels overlap the only way to read the information on screen is to reduce all text size, which has other readability issues.
Matthew Johnson about 1 month ago in InfoDrainage / Visualization 0 For Review