New docked quick graph view of selected object

When reviewing the model, I want an active graph panel I can dock anywhere that always shows me the selected object. Each time I select a new object, update the graph with the default output type. If possible, include option to select multiple obj...
Nathan Gerdts 16 days ago in InfoWater Pro / Productivity 0 Gathering support

Delete Vertex in Pipe

I would like to be able to remove vertices from a pipe. Currently, you can only move the vertices or redraw the pipe. This process takes a while on big models and makes the distribution network more complicated.
Guest 11 days ago in InfoWater Pro / Other 0 For Review

Easily query model results

Add the ability to easily query model results, such as: Junctions with pressure less than ## Pipelines with velocities higher than ## Valves with flow greater than ## etc. These could be added to a domain or viewed in the report manager. This is a...
Guest 2 months ago in InfoWater Pro / Productivity 2 For Review

Provide Velocity Constraint in Multi-Fireflow

Provide the ability to limit velocity for the multi-fireflow run option. Presently only the Fireflow run option offers a max velocity constraint capability; the Multi-Fireflow run option does not have a max velocity feature.
Guest 5 months ago in InfoWater Pro / Engine 0 Under consideration

Easily transform node from one type to another

Self explanatory. Use a user selection or domain.
Colin Ricks 5 months ago in InfoWater Pro / Productivity 0 Under consideration

Export and label nodes/pipes by their ID within generated HGL Profiles

Currently you are able to generate HGL profiles within the Report Manager. The data can only be labelled by their "head" value or by custom labels, however there is no option to label by their ID and to manually input every node turns into a heada...
Guest about 1 year ago in InfoWater Pro / Automation 2 Gathering support

InfoSurge velocity results

Please add pipeline velocities to the results for surge simulations. This really helps when designing surge tanks and connecting pipelines.
Guest about 2 months ago in InfoWater Pro / Engine 1 For Review

Default tank symbol

Can you change the default tank symbol color back to the dark blue that it used to be? The teal color is very light, making it difficult to see and hard to differentiate from the reservoir symbol. I know I can change this in preferences, but it wo...
Colin Ricks 5 months ago in InfoWater Pro / Productivity 0 Under consideration

Totalizer Valve and Controls

It would be very useful to have a totalizer valve which closes after a certain amount of flow passes through over a given time, such as 5 MGD over a day, then reopens once that time period has passed. Alternatively, a control option based on a pip...
Guest 6 months ago in InfoWater Pro / Operational Modeling 1 Under consideration

"Initially Closed" and "Check Valve Direction" symbology should adhere to the "show inactive elements" toggle

This is simple enough to do by adding a definition query on the MOTYPE field in conjunction with the existing DSPCODE filter, but currently I would have to manually change this for 4 layers every time I toggle display of inactive elements.
Eric King 5 months ago in InfoWater Pro / Other 1 In progress