Skip to Main Content
Autodesk
ADD A NEW IDEA

All ideas

Showing 1369 of 1369

Infiltration Trench using BRE DIGEST 365 method

The software needs to support for designing Infiltration trench method by using “BRE DIGEST 365”. I have checked the comparison between Infodrainage analysis Vs BRE digest 365 (manual calculation) and the results are not matching. Most of the proj...
Guest almost 2 years ago in InfoDrainage / Hydraulics 8 Gathering support

Infiltration surface in InfoWorks ICM

Within a part/selection of conduits, I want to know what the (infiltration) surface area is below a certain level (m AD). For example, what is the surface area of the ditch (bottom and sidewalls) up to a level of e.g., 4.0 or 5.0 m AD. Using Model...
Guest almost 2 years ago in InfoWorks ICM / Other 0 Gathering support

Enable resolution setting when view is stored in clipboard or files

When simulation results are summarized and reported, network data is printed after nicely arranged. In ICM, there is no way to define the resolution of views and it can deteriorate the printed views when they are output in large papers. Could you ...
Miyuki Okuda almost 2 years ago in InfoWorks ICM / Printing 0 Gathering support

Faster release Exchange license

After a user uses the Exchange license, it takes ages before the license is released again so another user can use it.
Marcel Glasbergen over 3 years ago in InfoWorks ICM / API / Exchange 2 Will not implement

odour

Air Phase Model Function - Can Innovyze consider to include air phase modelling function in InfoWorks? At moment, the odour modelling is done separately by various methods using the sewer hydraulic data as the input. As a result, the odour modelli...
XJ Wang over 3 years ago in InfoWorks ICM / Pollutants / Water Quality 0 Gathering support

As a CCTV inspection data manager I would like to be able to import and export inspections according both the BEFDSS_01_01 AND BEFDSS_02_01

As a CCTV inspection data manager I would like to be able to import and export inspections according both the BEFDSS_01_01 AND BEFDSS_02_01 Standard (NBN EN 13508-2:2003 → BEFDSS_01_01 and NBN EN 13508-2:2003+A1:2011 → BEFDSS_02_01) because this i...
Ilse Bisson over 2 years ago in Other Product Ideas / Asset Management 0 For Review

Swale with pipe under connected by manholes

Could not model real-life scenario where the pipe was under as conveyance for lesser events and raised via vented manholes into the swale above. Need integrated solution and was unable to model both and connect via manholes.
Guest almost 2 years ago in InfoDrainage / Hydraulics 1 Already exists

2D simulations failing due to bad geometry polygons

The issue involves a simulation failing due to a bad geometry building polygon. Although there was no critical error during the meshing process, the simulation failed at the initialization stage. In this particular instance, the client resolved th...
Guest 11 months ago in InfoWorks ICM / Errors 1 Will not implement

Hydrant Design Flow vs Available Flow!

I don't like the new update, which makes the available flow subject to a velocity constraint. In the previous version, the pressure constraint was on the hydrant flowing, while the design flow would consider the network pressure and pipes. They sh...
Guest 11 months ago in InfoWater Pro / Engine 0 For Review

Support for LACP v7 and v8

This is a request for support for LACP CCTV Management in Info360 Asset.
Martha Nunez over 2 years ago in Info360 Asset / CCTV Standards (e.g. PACP) / Rehab actions & cost 1 On roadmap