Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoWorks ICM

Showing 558 of 1423

Improve GIS engine

ICM stores everything, as coordinates in tables. This is especially an issue for polygons as polygons are just coordinates in a table. This means things like Donut polygons are not allowed and complex polygons produce countless annoying errors tha...
Andrew Sherson about 1 year ago in InfoWorks ICM / Import data 2 Gathering support

Save toolbar and screen configurations and locations

I run InfoWorks on my laptop, and have an external monitor. I find I'm often searching for toolbar buttons because switching between the two monitors of different sizes re-configures the locations of the various toolbars and screens. For example,...
Dave White over 6 years ago in InfoWorks ICM / Productivity 4 Gathering support

Export shapefile line features showing catchment loading when exporting network to GIS

This is really useful when interrogating / building the model in GIS. many of my clients have asked me if ICM will export the catchment loading arrows, and I have always had to say no.
Guest about 1 year ago in InfoWorks ICM / Export Data 2 For Review

Ability to use variables in range RTC rules

For RTC range rules, we want to be able to use variables instead of constant values for the minimum and maximum values.
Guest about 3 years ago in InfoWorks ICM / RTC 0 Gathering support

Enable running stats templates via ruby script

We are running more and more simulations via ruby script but then have to manually run the stats reports, then export the results this is very time consuming. It would be very useful to be able to run the previously created stats templates from th...
Graham Millar about 2 years ago in InfoWorks ICM / API / Exchange 0 Gathering support

Validation as a background task

Validation as a background task so UI isn't locked.
Guest over 6 years ago in InfoWorks ICM / Productivity / Validation 2 Will not implement

Improve database and results files read performance

When opening an ICM network for the first time (i.e. no network files in the local files "Working" folder), the WDS reads through the database file in 4 kB chunks to retrieve the requested version of the network. This read process appears to be li...
Peter Dunlop about 4 years ago in InfoWorks ICM / Performance / Results 3 Gathering support

Partially complete a simulation and review results and then opt to continue the simulation

Simulations often take a long time to run. I would like to be able to "pause" the simulation and review the results to check that the initialisation is correct, or that an RTC is working properly, and if I am happy then continue the simulation to ...
Ann Pugh over 6 years ago in InfoWorks ICM / Productivity / Reporting / Results / Simulations 2 Under consideration

In-sewer water temperature model

In-sewer water temperature monitoring has been around for a while. It is useful for identifying groundwater infiltration, potential heat recovery locations, optimising chemical dosing, predicting H2S build up and other key sewer processes. A dynam...
John Ward about 1 year ago in InfoWorks ICM / Simulations 4 Under consideration

Support for more than two simulations in long sections

When evaluating the effects of raising and lowering roughness it would be helpful to display three or more simulations in the same long section; at the moment it is only possible to display 2.
Richard Body about 6 years ago in InfoWorks ICM / Long Section / Profile / Productivity / Results 0 Gathering support