VSP Control based on Tank Head/Level

Currently you can only use Junction Pressure setpoints or Pump Flow setpoints in the VSP Control dialogue. It would be helpful to be able to use a Tank Level/Head setpoint to adjust the pump speed as well. This is possible in competitor products l...
Grant Clemens over 3 years ago in InfoWater Pro / Operational Modeling 3 Under consideration

Provide Velocity Constraint in Multi-Fireflow

Provide the ability to limit velocity for the multi-fireflow run option. Presently only the Fireflow run option offers a max velocity constraint capability; the Multi-Fireflow run option does not have a max velocity feature.
Guest over 1 year ago in InfoWater Pro / Engine 0 In progress

Add a new Special Query for "Demand Junctions" in the Domain Manager

Currently you have to either make your own tediously long query, or you can run a simulation and use output filters, but it should exist as a built-in Special Query.
Grant Clemens over 2 years ago in InfoWater Pro / Productivity 1 Gathering support

Pump control based on tank head

Pump control based on tanks are currently set to tank level. I would like the option to set according to tank head as well. I currently set tank minimum and maximum levels at their "real" elevations so that the levels in pump control can match up ...
Chris Keil 6 months ago in InfoWater Pro / Productivity 1 For Review

Allow more than 10 classes of Symbology in Map Themes

We have clients and models where there may be 15 to 20 different pipe sizes in their distribution system – It is extremely beneficial to be able to individually color-code and size-code them with symbology for easy reference. We used to be able to...
Guest 6 months ago in InfoWater Pro / Other 3 In progress

Option to "remember my choice" on the Query Set Cache pop-up

The pop-up asking whether to use the cache or re-run Query Sets every time you switch scenarios can get annoying. It would be nice to have a checkbox that says "always re-run queries" or something to that effect so that this pop-up can be suppressed.
Grant Clemens 10 months ago in InfoWater Pro / Productivity 0 Gathering support

Allow Constant Water Level in Tanks

We frequently need to run multiple time steps on steady-state simulations. Currently, to maintain a constant water surface elevation, we use a Reservoir element instead of a Tank. As a result, our models now include both a Tank (for non-steady-sta...
Joshua Alexander about 1 year ago in InfoWater Pro / Productivity 0 Gathering support

Make Scenario Explorer window panes resizable to see long Data Set names

When you resize the Scenario Explorer window, the left side with the Scenarios gets larger but the right side with Data Set / Facility / General tabs does not widen, so you can't see long Data Set names without opening a separate window.
Grant Clemens almost 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Batch Multi Fire Flow

I want the ability to model many different cases of multi-fire flow in parallel. This is important because I have many areas that require fire flow that is greater than what a single hydrant and later can achieve. Performing this manually for each...
Nathan Gerdts 10 months ago in InfoWater Pro / Automation 0 Gathering support

Totalizer Valve and Controls

It would be very useful to have a totalizer valve which closes after a certain amount of flow passes through over a given time, such as 5 MGD over a day, then reopens once that time period has passed. Alternatively, a control option based on a pip...
Guest over 1 year ago in InfoWater Pro / Operational Modeling 2 Under consideration