InfoWater Pro

Showing 106 of 1333

Isolation Scenario Using Dummy Valves Which Do Not Split Pipes

Can you put a valve on top of a pipe (not splitting the pipe) and then it closes the section? And then anything enclosed to these multiple valves will be isolated? This is going to be useful for modelling of isolation scenarios
Guest over 1 year ago in InfoWater Pro / Operational Modeling 3 Gathering support

Improvements to "Edit Attributes" table

The "Edit Attributes" window (accessed by using the "Edit Selection" or "Edit Domain" buttons) is a useful table to quickly view and edit all the physical information for each facility type together. However, it has some useability issues that som...
Colin Ricks over 1 year ago in InfoWater Pro / Productivity 0 Gathering support

inlet riser option for tank

Have an option to specify an Inlet Riser Pipe for the tank element. This would hold the fill head at a constant, set at the riser pipe elevation, but allow the tank discharge head vary with the tank level.
Guest over 4 years ago in InfoWater Pro / Engine 0 Gathering support

Report volume stored in all tanks

I can calculate volume from level, but it's an extra step and requires that I copy the run results out to Excel. It's even more difficult if I have a non-circular tank. Please include tank volume in the tank results and in the "System Demand" report.
Colin Ricks over 4 years ago in InfoWater Pro / Productivity 1 Gathering support

Hydrant and valve placement optimization

Hi there, We have been discussing the valve optimization in the whole County and if the InfoWater Pro can have the function to optimize the placements of hydrants and valves in the network to facilitate the design and high-level planning, that wou...
Guest almost 2 years ago in InfoWater Pro / Productivity 1 Gathering support

Account for multi-connection properties during criticality analysis

Some hospitals for example have multiple service laterals connecting them to the network. If one line is cut off from service due to a repair, the hospital can still get water. As a result, criticality is overestimated when this logic is ignored. ...
Nathan Gerdts about 2 years ago in InfoWater Pro / Other 0 Gathering support

Apply two-valve isolation for criticality analysis

For some projects we need to isolate the repair area with two closed valves in all directions in case one valve were to fail. Please incorporate this as an option in criticality analysis when summing affected customers
Nathan Gerdts about 2 years ago in InfoWater Pro / Other 0 Gathering support

Modify How InfoSurge Counts Features for Licensing

We have 20,000-pipe InfoSurge licenses. We frequently have operational models larger than that, where we want to perform Surge modeling. Even if we deactivate portions of the network, InfoSurge still counts the total number of features. This waste...
Guest over 4 years ago in InfoWater Pro 1 Will not implement

New Feature is Active in All Scenarios Option (InfoWater/Pro)

Add a tools/options option so when you add new features they will be active in all scenarios, instead of getting errors 100 times for every scenario you try to run where the features were not included originally. This would be especially useful wh...
Guest over 4 years ago in InfoWater Pro / Productivity 0 Gathering support

Simple Criticality Assessment Manager reporting in InfoWater Pro

I want a simple report for each pounded area between valves, reporting the length of pipe affected, number of customers, number of critical customers, amount of demand taken offline by isolation, and possibly the total volume of demand lost betwee...
Guest over 4 years ago in InfoWater Pro 0 Under consideration