Evaluate Fireflow Minimum Pressure by Zone

In the drop down menu for the Critical Node Search Range, please add the option to evaluate minimum pressure based on the same zone. Or add an option to consider multiple search areas where the user can select either the entire system and/or by zo...
Joe Lawrence over 4 years ago in InfoWater Pro 0 Gathering support

Export InfoSurge results for external application

InfoWater can use the option to "Export simulation results for external application" to export selected results to DBF files. It would be nice to have this work for InfoSurge.
Colin Ricks over 4 years ago in InfoWater Pro 1 Gathering support

GIS Gateway default Value

While updating the model from GIS and importing new objects, I want a user-defined Default value column for each field. If the source GIS is missing values, or there is no appropriate field to populate, fill in the model attribute using the defaul...
Nathan Gerdts over 1 year ago in InfoWater Pro / Data Exchange 1 Gathering support

Open Control Center on Selection, Selection Set, or Domain

For models with lots of controls, this would be helpful to quickly look a few at a time. For example, all the controls at a specific site. Right now, the list appears to be sorted randomly. It would also be helpful to automatically sort alphabetic...
Colin Ricks 10 months ago in InfoWater Pro / Productivity 0 Under consideration

Extend flexibility in displaying information associated to HGL profiles

As an InfoWater user I'd like to be able to add more information to my HGL profile, including nodal pressure, pipe diameter, flow, velocity, etc. I'd like see max/min level achieved throughout the simulation and have the ability to quickly add pip...
Guest almost 6 years ago in InfoWater Pro / Productivity 2 Gathering support

Report manager should populate without running model

Currently, the report manager is only populated once results are shown. This makes it so that the only place I can view the model data before running, is the data base manager. You should be able to have the report manager populated without runnin...
Endrit Shabani over 1 year ago in InfoWater Pro / Other 0 Gathering support

Flow direction arrows default symbology

By default, flow direction arrows show up as blue for forward flow, red for backwards flow. This is a pointless distinction because for distribution systems, "forwards" or "backwards" depends on the direction the pipe was initially digitized and h...
Colin Ricks over 2 years ago in InfoWater Pro / Productivity 0 Under consideration

Option for "downstream node" when allocating demand by pipe

The current "farthest node" option I believe just places the demand at the opposite end of the pipe compared to the meter point. Instead I'd like an option for all the meter demands to be placed at the pipe's end node. "Downstream" would probably ...
Eric King 11 months ago in InfoWater Pro / Other 0 For Review

Hydrant Design Flow vs Available Flow!

I don't like the new update, which makes the available flow subject to a velocity constraint. In the previous version, the pressure constraint was on the hydrant flowing, while the design flow would consider the network pressure and pipes. They sh...
Guest 11 months ago in InfoWater Pro / Engine 0 For Review

Persistent Graphs in InfoWater/InfoWater Pro

Stored graphs aren't that great. Why not just make graphs persistent?
Guest almost 5 years ago in InfoWater Pro / Productivity 2 Under consideration