Skip to Main Content
Autodesk
ADD A NEW IDEA

InfoDrainage

Showing 184 of 1228

Perforated Pipe as Connection Type

I would like to be able to model a perforated pipe as a connection type rather than use an infiltration trench and short branches of pipes to connect them to other stormwater controls. These infiltration trenches are not collecting inflow from sur...
Midori Patterson 12 months ago in InfoDrainage / Hydraulics 1 Gathering support

Manhole Types

Please allow us to specify manhole types (DMRB, SSG etc.) and covers and ensure that this data is visible in the manhole schedule export
Guest about 1 year ago in InfoDrainage / Productivity 1 Gathering support

Show manhole types in manhole schedule export

Manhole schedules need to feature cover types (D400, C250 etc), manhole types (Type A, B, C in Scotland etc) and whether they're a backdrop or a headwall etc. Having a feature to assign this based on location on site (cover type), depth to soffit ...
Guest 8 months ago in InfoDrainage / Productivity 0 For Review

Junction Loss

There need to be more options for calculating junction loss. Having values for entry and exit loss isn't enough. Recommend HEC-22 and AASHTO at a minimum.
Guest 7 months ago in InfoDrainage / Hydraulics 2 Gathering support

Add ability to create custom channel as underdrain (not just pipe)

Currently, you can only chose a pipe or multiple pipes as the underdrain within various features (infiltration trench, dry swale etc.). It would be great if a custom channel (section) could be used so an infiltration trench could be used to model ...
Guest 4 months ago in InfoDrainage / Hydraulics 0 For Review

Level Soffits in pipe network.

Although you can select Level Soffits in the Network Wizard, if you make a change in the manhole depth for example, the pipes in the network will return to invert level, which means that you will have to readjust them manually.
Konstantinos Koutroulis about 1 year ago in InfoDrainage / Hydraulics 1 In progress

Allow two Infodrainage files to be combined

Request for a paste, copy, cut branch to file options, to allow two Infodrainage files to be combined. As the available in Microdrainage
Guest 10 months ago in InfoDrainage / Other 1 Gathering support

Improve import to Civil 3D interface for multiple networks

When importing a second network into Civil 3D, the parts list option is locked and not the same as the parts list selected for the first network (both networks are within the same Infordrainage model).
Guest 5 months ago in InfoDrainage / Civil3D Integration 0 For Review

Pipe Intersection coordinates

Whilst setting the coords of a pipe intersection is a good feature, in certain common cases InfoDrainage does not allow for setting the correct setting of grade and levels of pipework, and due to its calculations can output levels against a certai...
Guest 7 months ago in InfoDrainage / Hydraulics 1 Gathering support

Bioretention Underdrain Slope / Additional layer Options

Virginia specifications for a bioretention requires the underdrain to have a slope to it, but Infodrainage slope does not allow for this in the SWC bioretention SWC. Also, we sometimes have to place the underdrains in a trench below the storage la...
Jenna Woyner 12 months ago in InfoDrainage / Hydrology 2 Already exists