Copy all settings from parent when creating new Scenario

When creating a new child Scenario, all the data sets are copied from the parent. However the Facility settings and General settings are ignored and the system defaults are used. Please copy all settings when creating new Scenarios to avoid errors.
Nathan Gerdts 12 months ago in InfoWater Pro / Productivity 0 Gathering support

Add summary statistic results for MSX outputs

I want to view Min, Max, and Avg statistics for my MSX results directly on the map so that I can summarize results spatially. Currently MSX results provide time-varying results for mapping of each species, but not the summary statistics across the...
Nathan Gerdts 12 months ago in InfoWater Pro / Water Quality 0 Gathering support

Open Control Center on Selection, Selection Set, or Domain

For models with lots of controls, this would be helpful to quickly look a few at a time. For example, all the controls at a specific site. Right now, the list appears to be sorted randomly. It would also be helpful to automatically sort alphabetic...
Colin Ricks 3 months ago in InfoWater Pro / Productivity 0 Under consideration

Batch run should work for run types other than standard

Batch run can only do standard runs. It is currently not possible to do fire flow, surge, pipe break, etc., as batch. Maybe add "Simulation type" to the General tab of the scenario explorer?
Colin Ricks 3 months ago in InfoWater Pro / Productivity 0 For Review

Move the Refresh Output checkbox

Refresh Output should be checked 99.9% of the time, if you accidentally uncheck it then you might unknowingly look at old results Map Displays do not update. Can this checkbox be moved to somewhere not in the Model Explorer so it is less likely to...
Grant Clemens 10 months ago in InfoWater Pro / Productivity 0 Gathering support

Option for "downstream node" when allocating demand by pipe

The current "farthest node" option I believe just places the demand at the opposite end of the pipe compared to the meter point. Instead I'd like an option for all the meter demands to be placed at the pipe's end node. "Downstream" would probably ...
Eric King 4 months ago in InfoWater Pro / Other 0 For Review

Hydrant Design Flow vs Available Flow!

I don't like the new update, which makes the available flow subject to a velocity constraint. In the previous version, the pressure constraint was on the hydrant flowing, while the design flow would consider the network pressure and pipes. They sh...
Guest 4 months ago in InfoWater Pro / Engine 0 For Review

Provide option to allow for several multipliers and use with selection sets

In addition to a global multiplier, sometimes you want to peak certain areas and selection sets with specific peaking factors. WaterCAD allows for this under their calculation options.
Michele Marston 9 months ago in InfoWater Pro / Operational Modeling 0 Gathering support

Group InfoWater Pro pumps into a pump station object that aggregates results

As a modeler I want to summarize the behavior of a pump station of multiple pumps using a polygon. This helps me summarize energy usage and total flow without needing to select arbirary upstream or downstream objects. This also helps simplify syst...
Guest over 3 years ago in InfoWater Pro / Operational Modeling 1 Gathering support

Ability to utilize an alternative asset ID for the Info360 Asset/Info360 Insight integration

Unfortunately, sometimes the InfoWater Pro model has different asset IDs compared to the source asset GIS. This makes the InfoWater Pro integration with Info360 Asset and Info360 Insight unusable when the source GIS is used in these products. The ...
Martha Nunez about 1 year ago in InfoWater Pro / Data Exchange 0 In progress