ICM SWMM should show the Pipe Slope and Full Flow (PFC) on the Properties Dialog

While it might seem like a small detail, the ability to access the same properties on a Grid in ICM SWMM that were available in InfoSWMM can significantly enhance user experience. Many users request to see properties such as pipe slope and PFC val...
Robert Dickinson about 1 year ago in InfoWorks ICM / Grids 0 Gathering support

Net rainfall results

Can we please have net/effective rainfall as a result?
Richard Body almost 5 years ago in InfoWorks ICM / Hydrology / Rainfall 0 Gathering support

2D Mesh Histogram

When meshing - it would be nice to see a Histogram of Mesh Zone Sizes.
Guest almost 2 years ago in InfoWorks ICM / Mesh 0 Gathering support

Ability to access databases where Workgroup Data Server and databases don't reside on same server

With the large amounts of data generated it would be beneficial if a supported configuration would be to have a WDS installed on a server but pointing at databases (and solves etc) over the network on a remote storage system (such as NAS). This wo...
Guest almost 5 years ago in InfoWorks ICM / Workgroup 0 Gathering support

Bridge section data updates

When a bridge section is changed then there are repeatable tasks for entering openings again, if this workflow could be improved that would be great.
Guest over 5 years ago in InfoWorks ICM / Bridge / Hydraulics 0 Gathering support

leave Layers and Themes window open

Could you make it possible to work in the Geoplan without having to close the Layers and Themes window? It would make switching Layers on and off much easier. Alternatively you could add a separate window to switch layers on and off.
Richard de Koning over 5 years ago in InfoWorks ICM / Productivity / Visualization 1 Gathering support

Drain nodes connected to 2d domain representing road gullies to 1D pipe network without digitised connection

Often datasets of road gullies are only in point format and lack details on the connections to the surface water sewer network. A function to allow 1D nodes representing road gullies (which are are connected to the 2D domain with a head discharge ...
Guest about 1 year ago in InfoWorks ICM / Inlets 0 Gathering support

Document that the pump with depth curve is not correctly converted.

Document that the pump with depth curve is not correctly converted.
John Krpan about 1 year ago in InfoWorks ICM / Errors 2 For Review

Control units precision in long plots and grid plots

it would be nice to be able to control unit precision such as volume in m3 to a whole number when reported volume is in the 400000 m3. we do not need to see 4 digits past the decimal!!
John Krpan about 1 year ago in InfoWorks ICM / Long Section / Profile 0 Gathering support

Speed up interfaces with 2D zones with millions of elements (make it a multicore process)

The interface for large 1D-2D models is very slow. While moving through the geoplan every time it takes about ten seconds to load and show the location. We noticed that in this time only 1 of the 32 CPU is used for 100%. We tried 2 complete differ...
Guest almost 5 years ago in InfoWorks ICM / Performance 1 Gathering support