Basin / Swale inlets pick up IL at point of entry, not the bed level

Inlets automatically pick up down stream bed level of SWC. Inlet pipes have to be locked, with the IL's calculated manually which can be difficult to get right along a basin or swale that is long and winding. Would it be possible for the IL pipe t...
Guest about 1 year ago in InfoDrainage / Productivity 0 For Review

Initial condition 1D setting value

For Initial Conditions 1D, InfoWorks ICM seems to specify 1) initial level(m AD) and inflow values at nodes for Nodes grid, 2) and initial depth (m) and flow values along the river reach for River Reaches grid. For river reaches grid, as an initia...
Guest about 1 year ago in InfoWorks ICM / InfoWorks 0 For Review

2D simulations failing due to bad geometry polygons

The issue involves a simulation failing due to a bad geometry building polygon. Although there was no critical error during the meshing process, the simulation failed at the initialization stage. In this particular instance, the client resolved th...
Guest 7 months ago in InfoWorks ICM / Errors 0 For Review

Hydrant Design Flow vs Available Flow!

I don't like the new update, which makes the available flow subject to a velocity constraint. In the previous version, the pressure constraint was on the hydrant flowing, while the design flow would consider the network pressure and pipes. They sh...
Guest 7 months ago in InfoWater Pro / Engine 0 For Review

InfoAsset Online - Add Head Discharge Grid and Graph

This appears to be missing in IAO yet it is present in IAM. It is needed in IAO.
Jim O'Dowd over 1 year ago in Other Product Ideas / Asset Management 0 For Review

Document that the pump with depth curve is not correctly converted.

Document that the pump with depth curve is not correctly converted.
John Krpan over 1 year ago in InfoWorks ICM / Errors 2 For Review

Correct resizing of pop-up windows activated through C3D toolbar

Due to issues with my eyesight I use the accessibility settings on my computer to increase the standard text sizes for applications. When using the InfoDrainage toolbar in Civil 3D pop-up menus don't resize to match the updated display settings. I...
Michael McWhinnie 8 months ago in InfoDrainage / Other 0 For Review

Make Cloud Db fully cloud

Cloud models can have locally referenced GIS data that makes portability difficult. An external GIS file (VPN path or network access data) referenced into a cloud database is not accessible if others don't have access to that same VPN path or netw...
Guest 8 months ago in InfoWorks ICM / Info360 Cloud 0 For Review

InfoAsset Manager: Condition grade profile

In InfoAsset Manager there is the facility to calculate a structural condition grade profile for each pipe (i.e. the % of the pipe in each condition grade). Currently this is only available for surveys scored using the MSCC. We originally collabo...
Guest almost 3 years ago in Other Product Ideas / Asset Management 5 For Review

Copy/Paste Run Setup messages

Currently you cannot copy/paste setup error/warning messages from the Schedule Hydraulic Run Window in order to further investigate. This feature would be particularly useful for troubleshooting more complex runs ie TS.