Skip to Main Content
Autodesk
ADD A NEW IDEA

Results

Showing 47 of 1249

As a User I want to use FME (safe.com) to manipulate model data, update the model & extract results.

No description provided
Guest almost 5 years ago in InfoWorks ICM / Data Exchange / Network / Results 0 Gathering support

Log locations that most often cause timestep halving during a simulation

The "Job Progress" window provides information of the location that cause multiple iterations or reduced time-steps in the 1D model, under the headings "Link fail H", "Link fail Q", "Node fail". This is useful for diagnosing potential locations of...
Manu Ward about 1 year ago in InfoWorks ICM / Results 2 Already exists

Modelling of Septicity

As a sewer modeller I have occasionally been asked about odour generation in sewer networks. I have noticed that DO (dissolved oxygen) and BOD (biochemical oxygen demand) are both inputs in the wastewater and trade-waste model groups of Infoworks ...
Guest over 5 years ago in InfoWorks ICM / Results / Simulations / Water Quality 0 Gathering support

Flags for tracing and long section

Placing flags at any node and having a "connect" button based on network connectivity leads to a big increase in workflow productivity. Flag tracing can be very useful for long section selection, upstream tracing from pump stations, and long secti...
Casey Shannon over 1 year ago in InfoWorks ICM / Results 1 Gathering support

split network results lines

it would be great if the "splitting lines" function can be applied to network results lines too, which would help a lot if we need to break up a large amount of NRLs into multiple segments rather than redrawing them.
Guest almost 2 years ago in InfoWorks ICM / Hydraulics / Results 0 Gathering support

Import HAZUS data into InfoWorks ICM Damage Functions

HAZUS data can be accessed from the backend using MS SQL. Could an import function be added to ICM which would allow a connection to the database and import data as needed to create damage functions?
Guest over 4 years ago in InfoWorks ICM / Hydraulics / Results / Simulations 0 Gathering support

I want the Show Maxima function to apply to Pipe Shear Stress

Currently, the "Show Maxima" results button doesn't apply to pipe Shear Stress (calculated through QM, Quality Module). It seems pipe Shear Stress is the only thing that Shear Stress is the only thing the "Show Maxima" results button doesn't app...
Guest over 4 years ago in InfoWorks ICM / Results 0 Gathering support