Relative file paths for CAD data etc.

Would it be possible to use relative file paths for attached information, such as CAD data. A lot of work is done on fileshare sites e.g. SharePoint. If one person syncs the model and another opens it, all the linked data is lost as the global fil...
Matthew Johnson almost 2 years ago in InfoDrainage / Data Exchange 0 For Review

Tank outlet pipe invert

Tanks outlet is usually above tank bottom level. It would be better to allow us to model tank outlet elevation relative to tank bottom elevation. This will increase accuracy in simulation, especially when we have multiple tanks in a tank farm and ...
Mohammed Abdallah 8 months ago in InfoWorks WS Pro / Modeler 0 For Review

Optimise Head / Discharge curves automatically for simulations

When simulating models, it is often necessary to consolidate the values in a H/Q curve to retain the hydraulic performance but optimize the simulation speed. As during previous correspondence with the InfoWorks support team, this has been advised ...
Tom Walker over 2 years ago in InfoWorks ICM / Orifice 2 Gathering support

Provide a "Remove elements from domain" option within DB Editor, Edit Domain Attributes, and tabular results report

I would like to be able to remove items from the domain as I review them within DB Editor, Edit Domain Attributes, and tabular results report tables, similar to the "Append to Domain" available when "right clicking" on an item in DB Editor.
Chris Keil 11 months ago in InfoWater Pro / Productivity 1 Gathering support

Give a warning when copying between networks with different user defined defaults

when copying for example conduits between networks with flags #D for headloss and roughness, the values are adapted to the user defined values in the new network. This can be confusing.
Guest over 3 years ago in InfoWorks ICM / Flags / Import data / Productivity 0 Gathering support

Cross section result view: keyboard shortcuts to go upstream or downstream

In the cross section result view (showing the water level), in RS there was the possibility to go upstream or downstream with PageUp/PageDwn, in ICM you have to right click to move upstream or downstream
Guest over 3 years ago in InfoWorks ICM / Productivity / Results / River Modeling 0 Gathering support

Bank line ground model update from within properties view

Make update from ground model possible from within properties view (as is already possible for cross sections)
Guest over 3 years ago in InfoWorks ICM / River Modeling 0 Gathering support

Ability to change mesh ground level values without remeshing

Mesh zones and Mesh level zones are available to change ground level values for the contained 2D meshes, but it will require re-meshing. If we can select 2D meshes by the polygon selection or selection tool and change the mesh elevation values wit...
Miyuki Okuda about 2 years ago in InfoWorks ICM / Mesh 1 Already exists

VSP Control based on Tank Head/Level

Currently you can only use Junction Pressure setpoints or Pump Flow setpoints in the VSP Control dialogue. It would be helpful to be able to use a Tank Level/Head setpoint to adjust the pump speed as well. This is possible in competitor products l...
Grant Clemens over 3 years ago in InfoWater Pro / Operational Modeling 3 Under consideration

Pipe Properties Table

It would be really nice to add a pipe properties management table to help manage roughness factors and wave speeds. This is a feature in KyPipe: Surge and it is extremely helpful when assigning wave speeds to pipelines. The table classifies pipe t...
Guest about 1 year ago in InfoWater Pro / Productivity 1 Gathering support