Skip to Main Content
Autodesk
ADD A NEW IDEA

InfoDrainage

Showing 190 of 1250

Sewer Design - Depth to soffit

InfoDrainage currently has the depths shown as depth to invert when depth to soffit is more useful to ensure the sewer has sufficient cover
Guest over 2 years ago in InfoDrainage 1 Under consideration

Provide Hydraulic Results in Civil 3D

As a Drainage Design user, I want to annotate the various Hydraulic results in plan and in profile within Civil 3D. I would like these results to automatically appear from my InfoDrainage design results.
Guest over 2 years ago in InfoDrainage 2 Under consideration

Improve Snap Marker visibility

Improve the Snap marker visibility as they blend into the object making the snap markers nearly invisible
Guest over 2 years ago in InfoDrainage 1 Already exists

Allow background mapping to be seen in plot plans

It would be good to allow shapefiles and other background mapping to be visible when creating a plot plan. Otherwise the location of pipework etc has no context.
Guest over 1 year ago in InfoDrainage / Other 1 Gathering support

Update downstream pipes

It would be useful to have an option to upsize downstream pipes automatically (just like microdrainage). For example, if i increase pipe size the corresponding downstream pipes should upsize accordingly so not to cause a restriction. At the minute...
Guest over 1 year ago in InfoDrainage / Productivity 2 Already exists

Import method specific Inflow parameters

With the various hydrology methods requiring additional parameters, it would be helpful to allow a feature to import these as GIS attributes. As methods such as SCS are widely used in the United States and require initial abstraction and curve num...
Sam Redway 12 months ago in InfoDrainage / Hydrology 1 Gathering support

Microdrainge to Revit

Make Pipes and Inlet available in Revit
Guest over 2 years ago in InfoDrainage 0 Gathering support

Print Tickbox for Manhole Schedule Layout option

In MicroDrainage 2019.1 the Manhole Schedule printout also includes a manhole layout, sometimes this is unnecessary and it would be helpful if there was an additional tickbox option in the printout settings.
Guest over 2 years ago in InfoDrainage 0 Gathering support

Allow SOIL values < 0.15

The Rural Runoff estimate tool in MDSUDS does not allow values of SOIL below 0.15. The UKSUDS greenfield runoff tool defaults to a value of SOIL=0.1 where SoilType=1 This produces a significant difference in results. This difference results from u...
Guest over 2 years ago in InfoDrainage 0 Gathering support

Design settings which only allows backdrops in pipe diameters below 225mm diameter

No description provided
Guest over 2 years ago in InfoDrainage 0 Gathering support