Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoDrainage

Update CAD data dynamically when updating externally (ie in C3D)

When you have cad data imported to an Infodrainage model you can’t update the data without it being closed i.e. in the example below I have the same drawing open in Civils 3D. So when a change is made and saved if you click reload cad data in Info...
Guest over 1 year ago in InfoDrainage / Civil3D Integration 0 For Review

Import EPASWMM5 Files

Importing EPASWMM5 files for US users would help to streamline the transition from SSA (you can export to SWMM5 from SSA)
Guest about 4 years ago in InfoDrainage 4 Under consideration

3D View of flooded manholes

The extent of flooding in the 3D view should be proportional to the volume of flooding of that manhole. At the moment it shows the same extent of flooding whether it's 0.1m3 or 100m3. Would make visualisation the extent and location of flooding on...
Guest over 2 years ago in InfoDrainage / Visualization 1 Already exists

Vary infiltration with depth

Cannot currently use the software for deisgn of borehole soakaways. By their very nature they wil have varying infiltration rates. Usually the infiltration is at greatest depth and no way of modelling with correct head in borehole.
Guest almost 2 years ago in InfoDrainage / Hydraulics 1 For Review

Allow underdrains to receive upstream flows from a pipe. Repair inflows to SuDS.

The SuDS nodes do not allow the inflows from an upstream pipe to connect directly to the underdrains. There are only options to connect them through no delays to subsurface areas (i.e. in bioretention nodes) or as a point inflow (i.e. filter drain...
Iwona Savas almost 2 years ago in InfoDrainage 0 For Review

Add ability to use custom curve number tables other than the default TR-55

Many jurisdictions publish their own set of curve numbers for different land uses which they will expect to see during plan review. The local curve number sets often differ from TR-55. Please allow us to build custom curve number sets based on lan...
Guest about 1 year ago in InfoDrainage / Hydrology 1 For Review

Add (change template) inlet from template to a junction without erasing the part family for the existing object

For example, in a model exported from Civil 3D, HEC-22 inlets need to be added to 100s of structures. The workflow is: 1. Create an Object Template for the HEC-22 inlet2. Right click each structure and change template to add a HEC-22 inlet The pro...
Daniel'le DeVoss almost 2 years ago in InfoDrainage / Hydraulics 2 For Review

Loss Method - Fraction with Maximum Loss

Hi - in SoCal and a local agency uses SCS loss method to create an average yield fraction rather than the typical loss curve, but with a maximum infiltration loss rate to "clip" the peak loss rate. Can we have a modified SCS loss method with max l...
Justin Brown 8 months ago in InfoDrainage / Hydrology 0 For Review

Plan View Annotation - Choose no. decimal places on pipe gradient value etc.

Displaying pipe gradients on plan (from Display Settings), which can be exported to CAD, is a very useful feature. However, when displaying pipe gradients, in the form 1: X, the X value is shown to 2 decimal places by default. It would be really u...
Dara Magee almost 2 years ago in InfoDrainage / Visualization 0 For Review

More informative Analysis Error messages in InfoDrainage

A common error in InfoDrainage is "The analysis has encountered an error and has been stopped." with no additional troubleshooting guidance, or hints about where the error originated. See some of the typical causes here: It would be helpful to hav...
Daniel'le DeVoss about 1 year ago in InfoDrainage / Auditing / Reviewing 2 Gathering support