Improve help documentation for Screen units

The InfoWorks ICM help file for screen units, contains an old illustration of a bar screen with an annotation to sum gaps between the bars to calculate spacing. This illustration is confusing as the help file for screens was recently changed to sp...
Tom Walker 6 months ago in InfoWorks ICM / Hydraulics 0 For Review

'Complex' Stormwater Control

It would be useful to add additional layers to bioretention structures. Currently the filtration layers only allow two layers. It would be useful to add far more. This would mean you could model a bioretention area above a soakaway, or attenuation...
Ian George about 2 months ago in InfoDrainage / Hydraulics 0 Gathering support

Pipe Flow Arrow size in Plan View

When looking at a network in the Plan View, the pipe flow arrow is very small. Please add an option in "View > Display Settings" to change flow arrow size
Ian George about 2 months ago in InfoDrainage / Visualization 0 Gathering support

Change subcatchment slope field to calculate correctly if non-numeric value used in Link Suffix.

When using InfoWorks ICM, if a network has a non-numeric link suffix in a conduit, the associated subcatchment slope field will not calculate. This results in a flat slope field and will affect run-off in simulations. Its not mentioned in the guid...
Tom Walker 8 months ago in InfoWorks ICM / Hydrology 0 For Review

Permeable paving needs to have a option for a different gradient at the surface to the gradient at the base.

This would allow a better representation of steep sites where we would otherwise lose a lot of storage, instead we can make the base flat to allow for more storage volume.
Guest 7 months ago in InfoDrainage / Hydraulics 1 For Review

Data exported to Geodatabase does not have the IAM, ICM, WS Pro selected projections

The IAM, ICM or WS Pro designated coordinate/projection system is NOT exported to ArcGIS feature classes when using the ODEC to export to a geodatabase. This means the user has to use the Define Projection tool in ArcGIS Pro in order to set the pr...
Tony Andrews 29 days ago in InfoWorks ICM / Export Data 0 For Review

Enable the Export to Geodatabase from Network > Export > Geodatabase in Autodesk 64 bit ICM, IAM, WSPro versions

In the Innovyze 32 bit ArcMap (ArcMap now deprecated) ICM, IAM and WS Pro software versions users could export in bulk to a Geodatabase. However, this functionality is greyed out in the Autodesk 64 Bit ArcGIS Enterprise version. It is very useful ...
Tony Andrews 29 days ago in InfoWorks ICM / Export Data 0 For Review

Attenuation Volume Summary Analysis

It would be useful to have access to a table that summarises all the attenuation volumes within the site include elements such as tanks, filter trenches, pipes, manholes etc. Similar to what was available in MicroDrainage
Guest over 1 year ago in InfoDrainage / Auditing / Reviewing 2 In progress

Resolve Design Wizard automatically introducing and accepting negative gradients along runs

The current design wizard in InfoDrainage, even when all design criteria are set to standard, allows for negative gradients to be included within the model and can often be missed without careful inspection or auditing. This then relies on going t...
Kyle Philander 5 months ago in InfoDrainage / Hydraulics 2 On roadmap

Add Trapezoidal Weirs for Pond Outlets

Trapezoidal weirs can be far more efficient as outlet structure devices than rectangular or v-notch weirs. I suppose using a rectangular and v-notch weir at the same time achieves the same goal, if you view a trapezoid as just a rectangular with t...
Andrew Newberry-Davis about 2 months ago in InfoDrainage / Hydraulics 0 For Review