Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 368 of 1442

Provide a "Remove elements from domain" option within DB Editor, Edit Domain Attributes, and tabular results report

I would like to be able to remove items from the domain as I review them within DB Editor, Edit Domain Attributes, and tabular results report tables, similar to the "Append to Domain" available when "right clicking" on an item in DB Editor.
Chris Keil 5 months ago in InfoWater Pro / Productivity 1 Gathering support

Add ability to see all pipes in Network Design Report

It is not possible to view the details / preliminary results of all the connections in the Network Design Report (each flow path needs to be selected in turn). This can be awkward for large networks.
Matthew Johnson over 1 year ago in InfoDrainage / Auditing / Reviewing 0 For Review

Optimising Parts Mapping

The parts mapping from Civil 3D to InfoDrainage can be quite tedious. Could we not have something like a vista table to view all connections and junctions in one table to see all parts at once and be able to change e.g a whole row to a connection ...
Guest about 1 month ago in InfoDrainage / Civil3D Integration 0 For Review

Set gradient and/or pipe size of multiple parts within a single flow path in one operation.

In some instances we need to change the gradient or pipe size of an entire flow path. It would be helpful if this could be done in one operation rather than each part individually. Any branch connections could also update to align unless locked.
Guest over 1 year ago in InfoDrainage / Productivity 2 Will not implement

Variable depth for open channels and swales

One limitation we are running into is the inability to model varying depths within swales in InfoDrainage. Often open channels will run along road corridors for example where the crest either remains at a similar elevation while the depth changes....
Guest almost 3 years ago in InfoDrainage / Visualization 3 In progress

Query “System Demand” results for “totalized” volume

It is universally understood that “the area under the curve” approximates the total volume of water for each of the “System Demand” output graphs in InfoWater Pro. Although a “Totalizer” can be applied to a pipe, it is not currently possible to qu...
Michael Kane 7 months ago in InfoWater Pro / Productivity 1 Gathering support

Amend & Simplify Report /Print Outputs

Would be useful to be able to fully customize the printed report outputs i.e. remove inlet, outlet information from controls, remove SuDS icons, remove unused or unimportant colums from results tables. It would also be good to be able to resize co...
David Williams over 1 year ago in InfoDrainage / Reporting 1 Under consideration

Pump and Valve symbol that indicates direction

The default symbols for Pumps and Valves should ideally indicate the direction they're pointing. This should involve dynamic symbol rotation based on connected pipes (not results). That way I can visually validate my data before running the model....
Nathan Gerdts 5 months ago in InfoWater Pro / Productivity 0 In progress

Changes to a network do not propagate downstream

If you change a pipe diameter or gradient, it will not accommodate these changes in the downstream section of the network. For example upsizing and steepening a pipe in the middle of a run will mean the next pipeis undersized and goes uphill. It a...
Matthew Johnson over 1 year ago in InfoDrainage / Hydraulics 1 For Review

Option to remove the 1m access chamber from cellular storage design

For a start, its not clear that the software actually does this, except one line in the help. So would probably be a good idea to make that clear. But the main issue is that I either need to mess with the volume or the porosity to make the volume ...
Guest 3 months ago in InfoDrainage / Hydrology 0 For Review