Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 1067 of 1442

Faster release Exchange license

After a user uses the Exchange license, it takes ages before the license is released again so another user can use it.
Marcel Glasbergen almost 4 years ago in InfoWorks ICM / API / Exchange 2 Will not implement

Drain nodes connected to 2d domain representing road gullies to 1D pipe network without digitised connection

Often datasets of road gullies are only in point format and lack details on the connections to the surface water sewer network. A function to allow 1D nodes representing road gullies (which are are connected to the 2D domain with a head discharge ...
Guest almost 2 years ago in InfoWorks ICM / Inlets 0 Gathering support

odour

Air Phase Model Function - Can Innovyze consider to include air phase modelling function in InfoWorks? At moment, the odour modelling is done separately by various methods using the sewer hydraulic data as the input. As a result, the odour modelli...
XJ Wang almost 4 years ago in InfoWorks ICM / Pollutants / Water Quality 0 Gathering support

Further "Set Area Codes" functionality - InfoWorks WS Pro

2 feature requests for consideration, both relating to the “set area codes” functionality in InfoWorks WS Pro: 1. The ability to save the “set area code” configuration, whether that be in a model tree group or as a cfg file, so that you don’t have...
Daniel Alexander almost 5 years ago in InfoWorks WS Pro 0 Gathering support

Control units precision in long plots and grid plots

it would be nice to be able to control unit precision such as volume in m3 to a whole number when reported volume is in the 400000 m3. we do not need to see 4 digits past the decimal!!
John Krpan almost 2 years ago in InfoWorks ICM / Long Section / Profile 0 Gathering support

Conduit Numbering

I have encountered a glitch with the conduit numbering system. While manhole numbering works as expected (check the snip), the conduit numbering is generating inconsistent formats as expected such as CO-1.001, CO.1002, and so on Our expectation is...
Jana Anbu 12 months ago in InfoDrainage / Productivity 2 Already exists

Exclude specific elements from Numbering Scheme (flow paths, manholes, simple junctions, etc).

Be able to have only manholes in the manhole schedule, without any missing manhole numbers. Junctions can be named separately and not included. Enable large sites with multiple areas to have their different areas named a different way easier.
Guest almost 2 years ago in InfoDrainage / Auditing / Reviewing 2 Gathering support

GIS Gateway default Value

While updating the model from GIS and importing new objects, I want a user-defined Default value column for each field. If the source GIS is missing values, or there is no appropriate field to populate, fill in the model attribute using the defaul...
Nathan Gerdts almost 2 years ago in InfoWater Pro / Data Exchange 1 Gathering support

Auto populate an incremental ID for objects such as lines/polygons/subcatchments etc.

Often source data is provided with a non unique ID. Nodes auto generate an ID, and conduits will create a node, but the remaining asset classes struggle somewhat and often you need to manipulate the GIS data. I would like to be able to have ICM...
Ann Pugh almost 6 years ago in InfoWorks ICM / Data Exchange / GIS Layers / Import data 0 Gathering support

Merge more than two polygon in one go

Merging polygons representing for instance mesh zones can help reducing the number of triangles, particularly small ones, and reduce simulation time. The version of ICM I am using can only merge two polygons at the time. I currently do the polygon...
francisco simon about 6 years ago in InfoWorks ICM / Data Exchange / Productivity 0 Gathering support