Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoDrainage

Resolve Design Wizard automatically introducing and accepting negative gradients along runs

The current design wizard in InfoDrainage, even when all design criteria are set to standard, allows for negative gradients to be included within the model and can often be missed without careful inspection or auditing. This then relies on going t...
Kyle Philander 6 months ago in InfoDrainage / Hydraulics 2 On roadmap

Add Manhole 'clocks' to the manhole schedule

It would be useful to show a basic plan view of the manholes in the manhole schedules (with inlets and outlet alignments accurately shown). This is useful when contractors order per-cast manhole bases that require 'clock' diagrams.It would be real...
Ian George 9 months ago in InfoDrainage / Other 0 Gathering support

Would it be possible to include longitudinal gradient (slope) to attenuation tanks please? At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet.

At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet (and this could then change the head of wate...
arek kadlec over 2 years ago in InfoDrainage / Hydraulics 1 Gathering support

Addition of infiltration flows to foul drainage models in subcatchment items

When designing foul pipe networks, client guidance often directs users to incorporate an allowance for infiltration into pipes from the surrounding ground water. This is applied in addition to foul flows currently defined using the Main Drainage/ ...
Michael McWhinnie about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Allow different C-values (runoff coefficients) for major and minor storms

It would be nice to have an input for different C-values (runoff coefficients) for various storm events. In CO we have different coefficients based on the storm event which contributes to the flow calculations for the Rational Method. Currently yo...
Steve Batchelder 7 months ago in InfoDrainage 0 For Review

‼️Improved Snapping and Placement Tools ‼️

It would be great to have additional snapping options—simple ones like end, midpoint, and intersection—to make placement more accurate. Currently, snapping is inconsistent and often doesn’t engage when expected. It would also help to clearly show ...
Guest 7 months ago in InfoDrainage 1 For Review

Continuous Matched Soffits or Inverts Snapping

It would be useful if all pipes in a junction automatically snapped to match either soffits or inverts. There is a variable in the Network Design Criteria for 'Level Soffits' or 'Level Inverts' so potentially this option could be used for the live...
Ian George 9 months ago in InfoDrainage / Productivity 0 Gathering support

Import Civil 3D surface directly to Infodrainage

Importing a Civil 3D surface directly would eliminate any errors in the conversion process, ensuring triangulations are accurate and surface boundaries are observed
Guest 10 months ago in InfoDrainage / Civil3D Integration 0 Gathering support

Add ability to see all pipes in Network Design Report

It is not possible to view the details / preliminary results of all the connections in the Network Design Report (each flow path needs to be selected in turn). This can be awkward for large networks.
Matthew Johnson almost 2 years ago in InfoDrainage / Auditing / Reviewing 0 For Review

Pipe Flow Arrow size in Plan View

When looking at a network in the Plan View, the pipe flow arrow is very small. Please add an option in "View > Display Settings" to change flow arrow size
Ian George 3 months ago in InfoDrainage / Visualization 0 Gathering support