Addition of infiltration flows to foul drainage models in subcatchment items

When designing foul pipe networks, client guidance often directs users to incorporate an allowance for infiltration into pipes from the surrounding ground water. This is applied in addition to foul flows currently defined using the Main Drainage/ ...
Michael McWhinnie about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Add Manhole 'clocks' to the manhole schedule

It would be useful to show a basic plan view of the manholes in the manhole schedules (with inlets and outlet alignments accurately shown). This is useful when contractors order per-cast manhole bases that require 'clock' diagrams.It would be real...
Ian George 10 months ago in InfoDrainage / Other 0 Gathering support

Add option to show multiple storm results in side by side columns in Flexible Reporting

We need to be able to show the results of multiple storm events per network element in side by side columns on a single page. See attached image
Daniel'le DeVoss 3 months ago in InfoDrainage / Reporting 0 For Review

Manhole Schedule in a dendritic order

It would be handy to have the Manhole Schedule under Print--> Manhole Schedule to be shown in a dendritic order
Pietro Albano 5 months ago in InfoDrainage / Reporting 0 In progress

Single Table for all the Manhole/Junctions

At the moment under table-->Junction it is only possible to add the Manhole/Junction associated to a Flow Path. There should be a command that allows to displays all Manhole/Junctions of the Phase in a unique single table.
Pietro Albano 5 months ago in InfoDrainage / Reporting 1 Already exists

Resolve Design Wizard automatically introducing and accepting negative gradients along runs

The current design wizard in InfoDrainage, even when all design criteria are set to standard, allows for negative gradients to be included within the model and can often be missed without careful inspection or auditing. This then relies on going t...
Kyle Philander 8 months ago in InfoDrainage / Hydraulics 2 On roadmap

'Complex' Stormwater Control

It would be useful to add additional layers to bioretention structures. Currently the filtration layers only allow two layers. It would be useful to add far more. This would mean you could model a bioretention area above a soakaway, or attenuation...
Ian George 5 months ago in InfoDrainage / Hydraulics 0 Gathering support

Allow different C-values (runoff coefficients) for major and minor storms

It would be nice to have an input for different C-values (runoff coefficients) for various storm events. In CO we have different coefficients based on the storm event which contributes to the flow calculations for the Rational Method. Currently yo...
Steve Batchelder 8 months ago in InfoDrainage 0 For Review

Add Trapezoidal Weirs for Pond Outlets

Trapezoidal weirs can be far more efficient as outlet structure devices than rectangular or v-notch weirs. I suppose using a rectangular and v-notch weir at the same time achieves the same goal, if you view a trapezoid as just a rectangular with t...
Andrew Newberry-Davis 5 months ago in InfoDrainage / Hydraulics 0 For Review

Catchment time of concentration automatic calculation

do you know how anoying having hundreds of catchments but i need to manually use time of concentration calculator. there are already soil type, land cover, land use i inputted. just make a table input so i can calculate it automatically
Guest 3 months ago in InfoDrainage / Hydrology 0 For Review