Add a storage structure feature for channel drains

Add a storage structure feature for channel drains (e.g. channel, slot drain, kerb drain) so that these features can be presented as storage and not only conveyance (by modelling a custom section) and so that catchments can be connected as a sheet...
Guest 29 days ago in InfoDrainage / Hydraulics 0 For Review

Would it be possible to include longitudinal gradient (slope) to attenuation tanks please? At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet.

At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet (and this could then change the head of wate...
arek kadlec 8 months ago in InfoDrainage / Hydraulics 1 Gathering support

Option to remove the additional storage automatically added in geocellular systems

When designing a cellular soakaway, infodrainage automatically assumes a 1m2 plan area chamber between tank soffit and exceedance level (which would have been specified as ground level). In other structures you can specify freeboard and exceedance...
Guest about 1 month ago in InfoDrainage / Hydraulics 0 For Review

Permeable Pavement with varying depth

Please add an option to input the surface slope and formation level slope for the permeable pavements to represent the varying depth of storage below. This is one of the 3 options we use at steeper sites to provide adequate storage in permeable pa...
Dilraj KT 3 months ago in InfoDrainage / Hydraulics 0 For Review

Order Junction & Connection Results Printout by Flowpath (to match the Model Printout)

Issue: When using the 'print' feature, if a flow path is selected, the model summary for junctions will show ALL connected pipes, in 'flow' order, which is very useful for presenting/understanding data. However, in the results tab for connections,...
Alex Purcell 5 months ago in InfoDrainage / Reporting 0 For Review

Improve import to Civil 3D interface for multiple networks

When importing a second network into Civil 3D, the parts list option is locked and not the same as the parts list selected for the first network (both networks are within the same Infordrainage model).
Guest about 2 months ago in InfoDrainage / Civil3D Integration 0 For Review

Show manhole types in manhole schedule export

Manhole schedules need to feature cover types (D400, C250 etc), manhole types (Type A, B, C in Scotland etc) and whether they're a backdrop or a headwall etc. Having a feature to assign this based on location on site (cover type), depth to soffit ...
Guest 5 months ago in InfoDrainage / Productivity 0 For Review

Liquid filled/Flooded drainage network

Liquid filled/Flooded drainage network- the system should be required to design flooded drainage network i.e. drainage pipe should be always filled with liquid for entire length up to the discharge point. Like a surcharge up to manhole cover (liqu...
Guest about 2 months ago in InfoDrainage / Hydraulics 0 For Review

Perforated Pipe as Connection Type

I would like to be able to model a perforated pipe as a connection type rather than use an infiltration trench and short branches of pipes to connect them to other stormwater controls. These infiltration trenches are not collecting inflow from sur...
Midori Patterson 9 months ago in InfoDrainage / Hydraulics 1 Gathering support

Junction Loss

There need to be more options for calculating junction loss. Having values for entry and exit loss isn't enough. Recommend HEC-22 and AASHTO at a minimum.
Guest 4 months ago in InfoDrainage / Hydraulics 2 Gathering support