Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 659 of 1372

"Initially Closed" and "Check Valve Direction" symbology should adhere to the "show inactive elements" toggle

This is simple enough to do by adding a definition query on the MOTYPE field in conjunction with the existing DSPCODE filter, but currently I would have to manually change this for 4 layers every time I toggle display of inactive elements.
Eric King 11 months ago in InfoWater Pro / Other 1 In progress

Add an option to automatically Refresh All graphs in the Report Manager after a new run.

Currently when you complete a new run you have to remember to hit Refresh All in the Report Manager to see latest results. The use-case for viewing old run results is rare, so having an option to automatically refresh all graphs and tables would b...
Grant Clemens over 1 year ago in InfoWater Pro / Productivity 0 Gathering support

More flexibility for pdm runs

We would like to be able to simulate warmup and hydraulic simulations with different input sources. Now the run crashes if for example rainfall data does not match the saved state of the warmup run. It would also be very useful to make it possible...
Guest almost 3 years ago in InfoWorks ICM / Hydrology 0 Gathering support

Better functionality for multiruns

- number episodes in episode collection - sort runs according to number - greater timesteps for runoff only runs - resume with next run if a run fails - easy export of maximum results of runs (without results of the runoff only runs)
Guest almost 3 years ago in InfoWorks ICM / Simulations 0 Gathering support

Automated Calibration Tool

Tool similar to competing software where you can apply a level (%) of uncertainty and automatically sun simulations with varied parameters withing that level of uncertainty and see all results at once.
Guest over 5 years ago in InfoWorks ICM / Calibration 2 Gathering support

Modify Peaking Constant/Shape Factor in SCS Routing Model

There isn't a good way to modify the peaking constant also referred to at the shape factor for developing an SCS hydrograph in ICM networks. The most common is 484 which is the constant used in an ICM network, but there are occasional needs to mod...
Ryan Brown over 1 year ago in InfoWorks ICM / Hydrology 5 Under consideration

Make Scenario Explorer window panes resizable to see long Data Set names

When you resize the Scenario Explorer window, the left side with the Scenarios gets larger but the right side with Data Set / Facility / General tabs does not widen, so you can't see long Data Set names without opening a separate window.
Grant Clemens about 1 year ago in InfoWater Pro / Productivity 0 Gathering support

Allow for the running of statistics templates and generation of grid reports such as RPA and worst case using ICM Exchange

No description provided
Guest over 5 years ago in InfoWorks ICM / API / Exchange / Productivity / Results 0 Gathering support

Possibility to turn off report windows

Now, when updating elements from ground model, extending cross sections, inserting an opening in a bridge… a report is displayed. This can be very annoying when building up a model and you have to click the report windows away. It would be useful ...
Guest almost 3 years ago in InfoWorks ICM / Mesh / Productivity 2 Gathering support

Include regulator state in graph reports

this can only be done with custom graphs, would be easier in standard graphs for run comparison
Guest almost 3 years ago in InfoWorks ICM / Results 0 Gathering support