Infiltration Basins

The output tables for ponds doesn't include any infiltration outputs where the pond is an infiltration basin. The graphs show that there is infiltration but MicroDrainage used to include infiltration in the output table
Guest over 3 years ago in InfoDrainage 2 Under consideration

Calculation of Pump Power in ICM

A pump curve and energy/efficiency curve can be input into the software however there is no way to output the energy used by the pump. South Gippsland Water were keen on understanding whether ICM could do this to report their energy efficiency bas...
Ann Pugh almost 5 years ago in InfoWorks ICM / Pumps 0 Gathering support

Be able to drag the grid window off main interface to another monitor.

Drag grid window to another screen, just like an attribute table in ArcMap/ArcGIS Pro. Allowing more relaxed and open use of grids, with much less scrolling through tight windows.
Guest almost 5 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 0 For Review

Multiple control options

Assets with controls (Pumps, PRVs etc.) should have multiple control options. So Control 1 could be a control regime applicable to model calibration. Control 2 could be control relevant to a General Applications model, Controls 3, 4, 5 etc c...
Guest almost 5 years ago in InfoWorks WS Pro / Productivity 1 Already exists

Export both the result and the underlying property fields

When the model results are displayed on the webpage through Exchange, since the basic properties need to be viewed, the corresponding basic properties of the results need to be exported first, and then the results are matched to the basic properti...
Liu Qiusheng about 5 years ago in InfoWorks ICM / Export Data / Simulations 0 Gathering support

Convergence Errors be resolved automatically while the model is simulated

Sometime a TSR running for few weeks throws up convergence hence these sims need to be rerun with shorter timestep which is both inefficient and a lot of time is wasted. It would be good if somehow the simulations dialog allowed to run the model w...
Salam Jamadar about 5 years ago in InfoWorks ICM / Performance / Simulations 0 Gathering support

Allow Theming Inflow areas by attributes

I would like to visually theme the Inflow areas by an attribute, say, Percent Impervious (PIMP)
Guest over 3 years ago in InfoWorks ICM / Theme / Visualization 0 Gathering support

Report showing history of simulation jobs running on server over a period of time

We are aware that ICM simulation jobs that are currently running on a simulation server can be viewed in the agent.state file in D:\Innovyze\InfoWorksAgent on the server. It would be great if there were a report that could show the history of ...
Mark Huxtable over 1 year ago in InfoWorks ICM / Statistics 0 Gathering support

Can the simulation log file be broken up into sections

Can the simulation log file be broken up into sections, as models get bigger and many with several 2d zone trying to find what is actual causing a simulations failure is becoming a bit more difficult having to scroll through big log files for that...
Bob Fleming about 5 years ago in InfoWorks ICM / Errors / Reporting 0 Gathering support

Integration and visualization of Electroscan data

Electroscan data is a condition assessment technology that uses current readings to detect potential infiltration and inflow defects along the length of the pipe. The current vs length readings can be displayed in a plot diagram in InfoAsset Plann...