Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 144 of 1372

Enhance import/export of SWMM models for ICM platform

Enhance model import from SWMM5 INP files to include a few of the Open Data Import Center /Open Data Export Center options: • Only update existing records • Ignore existing objects • Overwrite, Merge, etc. • Export Selection only Ultimately we wan...
Guest over 5 years ago in InfoWorks ICM / Export Data / Import data / InfoWorks / SWMM 1 Gathering support

Specify number of demands

I almost never need to use all 10 demand fields in InfoWater. The ability to specify the number of demand fields needed would save space in the demand DB table and in the Model Explorer window and make viewing these windows easier.
Colin Ricks almost 6 years ago in InfoWater Pro / Other 3 Under consideration

Consistent SHP Export Data Fields for 2D mesh elements in ICM

A simulation result can be exported to SHP files by right clicking the icon and choosing the Export menu. When the result is exported for a specific timestamp, some underlying data fields are not exported such as the elevation and area of a 2D ele...
Miyuki Okuda over 4 years ago in InfoWorks ICM / Export Data 0 Gathering support

Allow Customized Reports to Also Include Standard and Fireflow Results - Just Have One Result Table

Currently all model element information and results are separated between the DB Editor, Customizable Report, and Output Report/Graph. This is confusing and hard to export specific information together without having to combine it later in Excel o...
Joe Lawrence over 4 years ago in InfoWater Pro 1 Gathering support

Include an "excluded search nodes" warning in fireflow output table

When the design pressure exceeds the static pressure at a particular node, that node will be excluded from a design fireflow model run. The output table should include a banner at the top listing the excluded nodes, as these can make a big differe...
Guest over 4 years ago in InfoWater Pro / Engine 0 In progress

inlet riser option for tank

Have an option to specify an Inlet Riser Pipe for the tank element. This would hold the fill head at a constant, set at the riser pipe elevation, but allow the tank discharge head vary with the tank level.
Guest almost 5 years ago in InfoWater Pro / Engine 0 Gathering support

Export both the result and the underlying property fields

When the model results are displayed on the webpage through Exchange, since the basic properties need to be viewed, the corresponding basic properties of the results need to be exported first, and then the results are matched to the basic properti...
Liu Qiusheng almost 5 years ago in InfoWorks ICM / Export Data / Simulations 0 Gathering support

Isolation Scenario Using Dummy Valves Which Do Not Split Pipes

Can you put a valve on top of a pipe (not splitting the pipe) and then it closes the section? And then anything enclosed to these multiple valves will be isolated? This is going to be useful for modelling of isolation scenarios
Guest almost 2 years ago in InfoWater Pro / Operational Modeling 3 Gathering support

Improvements to "Edit Attributes" table

The "Edit Attributes" window (accessed by using the "Edit Selection" or "Edit Domain" buttons) is a useful table to quickly view and edit all the physical information for each facility type together. However, it has some useability issues that som...
Colin Ricks almost 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Hydrant and valve placement optimization

Hi there, We have been discussing the valve optimization in the whole County and if the InfoWater Pro can have the function to optimize the placements of hydrants and valves in the network to facilitate the design and high-level planning, that wou...
Guest about 2 years ago in InfoWater Pro / Productivity 1 Gathering support