When importing BEFDSS CCTV surveys allow for update by ID.

When importing CCTV surveys following the BEFDSS (Belgian) standard, it's only possible to update existing surveys by matching on AAD + AAF + ABJ fields. It would make our lives a lot easier when it would be possible to update existing surveys by ...
Ward Delabastita 6 months ago in Other Product Ideas / Asset Management 0 For Review

plotting multiple HGL simulations (more than 2) in one HGL profile

This would be useful to compare various scenarios/HGL in one profile. It would be helpful for visualization, understanding, and presenting results.
Guest 2 months ago in InfoWorks ICM / Long Section / Profile 0 For Review

Add ability to see all pipes in Network Design Report

It is not possible to view the details / preliminary results of all the connections in the Network Design Report (each flow path needs to be selected in turn). This can be awkward for large networks.
Matthew Johnson over 1 year ago in InfoDrainage / Auditing / Reviewing 0 For Review

weighted roughness value according to the % of rougness zone within the 2D element

We have more and more detailed data and detailed models. This results into very detailed land use polygons then very detailed roughness zones. It means that a 2D element can contain several roughness zones. Intead of using the barycenter of the 2D...
Armonie COSSALTER 4 months ago in InfoWorks ICM / 2D Flooding 1 For Review

Enable 3D video in defects tab of surveys

3D video can provide additional insight for sewer inspections (manhole & CCTV). As of now, the viewer in the defects tab doesn't have the standard panning functionality necessary for viewing 3D video.
Guest 10 months ago in Other Product Ideas / Asset Management 2 For Review

Changes to a network do not propagate downstream

If you change a pipe diameter or gradient, it will not accommodate these changes in the downstream section of the network. For example upsizing and steepening a pipe in the middle of a run will mean the next pipeis undersized and goes uphill. It a...
Matthew Johnson over 1 year ago in InfoDrainage / Hydraulics 1 For Review

Add max pipe flow to the pipe properties window

Max pipe flow (theoretical pipe full) is not listed in pipe properties, as it was previously in MicroDrainage. It was a useful feature.
Ian George 3 months ago in InfoDrainage / Productivity 0 For Review

Downstream pipes matching soffits/inverts

Currently when making changes in InfoDrainage the downstream pipes do not automatically adjust to the lowest incoming pipe. This means we have to manually adjust (and usually then lock) most pipes which is a downgrade from MicroDrainage.I understa...
Ian George 3 months ago in InfoDrainage 0 For Review

Slope in %

It would be very handy if the slope input option of % be present regardless of Regional settings; being just 1:x is an important limitation; also, if the slope in % could be shown in the section views, would be nice.
Guest 12 months ago in InfoDrainage / Hydraulics 0 For Review

SCS generation - automatically pull data

InfoDrainage says it 'Generate(s) SCS data' but it really just links to the SCS website. Can Autodesk refine this to be more like the NOAA Atlas 14 which really does pull the data automatically into InfoDrainage.
Tim Medearis 9 months ago in InfoDrainage / Rainfall 0 For Review