Skip to Main Content
Autodesk
ADD A NEW IDEA

All ideas

Showing 1387 of 1387

Depths, Velocity and Hazard raster creation

it would be great if ICM could include a tool to create multiple rasters. I understand that generating the initial 2D shapefile and processing the results to find the maximum values is the hard task. But once this shapefile is ready, converting it...
Gamaleldin Essam 9 months ago in InfoWorks ICM / Sharing 1 Under consideration

possibility to connect labels to links at the beginning or end instead of only in the middle of the link

This way you can show that link invert levels on a manhole differ in value or deviate from the chamberfloor
Loes van der Linden 11 months ago in InfoWorks ICM / Labels 3 Already exists

Freeboard in Results

When freeboard is exceeded from something like a basin, it is not immediately clear in the stormwater control results. It says flood risk and a water level that eats into the freeboard, but it does not flag up that this is an issue and is easily m...
Guest 8 months ago in InfoDrainage / Hydraulics 0 For Review

Tools to clean up networks using the SWMM engine.

At the moment, the inference tools only work in a Wallingford network, and no tools are available in a SWMM network.
Guest 3 months ago in InfoWorks ICM / SWMM 3 Will not implement

Improve ground infiltration simulation parameters.

Could we have a 'Node level affects groundwater infiltration' for the soil store please? This simulation parameter was introduced to InfoWorks ICM recently to limit infiltration from the ground store to the model. Could this be extended to limit f...
Tom Walker over 4 years ago in InfoWorks ICM / Calibration / Groundwater / Hydrology 0 Gathering support

Set gradient and/or pipe size of multiple parts within a single flow path in one operation.

In some instances we need to change the gradient or pipe size of an entire flow path. It would be helpful if this could be done in one operation rather than each part individually. Any branch connections could also update to align unless locked.
Guest over 1 year ago in InfoDrainage / Productivity 2 Will not implement

Repeat Table Headers on each page

The report tables currently display the table headers once under each return period / critical event. If the headers were repeated on each page, the tables would be easier to read. Thanks
Guest 8 months ago in InfoDrainage / Reporting 1 Gathering support

Pump and Valve symbol that indicates direction

The default symbols for Pumps and Valves should ideally indicate the direction they're pointing. This should involve dynamic symbol rotation based on connected pipes (not results). That way I can visually validate my data before running the model....
Nathan Gerdts 3 months ago in InfoWater Pro / Productivity 0 In progress

Add ability to see all pipes in Network Design Report

It is not possible to view the details / preliminary results of all the connections in the Network Design Report (each flow path needs to be selected in turn). This can be awkward for large networks.
Matthew Johnson over 1 year ago in InfoDrainage / Auditing / Reviewing 0 For Review

Amend & Simplify Report /Print Outputs

Would be useful to be able to fully customize the printed report outputs i.e. remove inlet, outlet information from controls, remove SuDS icons, remove unused or unimportant colums from results tables. It would also be good to be able to resize co...
David Williams about 1 year ago in InfoDrainage / Reporting 1 Under consideration