Convergence Errors be resolved automatically while the model is simulated

Sometime a TSR running for few weeks throws up convergence hence these sims need to be rerun with shorter timestep which is both inefficient and a lot of time is wasted. It would be good if somehow the simulations dialog allowed to run the model w...
Salam Jamadar almost 5 years ago in InfoWorks ICM / Performance / Simulations 0 Gathering support

Document how results pfc vs r.pfc are calculated for open channels

in the long plots we ask for two capacities, we get pfc vs r.pfc for pipes they are the same , but for open channels such a trapezoidal they are different. there seems to be no literature on this.
John Krpan over 1 year ago in InfoWorks ICM / Results 3 Will not implement

Can the simulation log file be broken up into sections

Can the simulation log file be broken up into sections, as models get bigger and many with several 2d zone trying to find what is actual causing a simulations failure is becoming a bit more difficult having to scroll through big log files for that...
Bob Fleming almost 5 years ago in InfoWorks ICM / Errors / Reporting 0 Gathering support

Live CCTV feeds into workspaces

Customers managing irrigation schemes using CCTV cameras to monitor the various elements of the scheme. Having live feeds available on a workspace would enhance user experience and scheme monitoring capability. Video does not need to be stored, ju...
Brad Thompson over 1 year ago in Info360 Insight / Workspaces 0 For Review

Option to pan through 2 or multiple geoplans at the same time

Sometimes (in ICM and IAM) in comparing 2 (or more) networks visually the networks are most of the time tiled horizontally of vertically. But when panning through one network, it would be very convenient that the other network(s) is/are also movin...
Guest about 5 years ago in InfoWorks ICM / Productivity 0 Gathering support

Report InfoSWMM available capacity against theoretical flow for specified d/D

InfoSWMM provides Pipe/Conduit summary report with values for Max flow divided by "Full Flow". Here the "full flow" is based on Manning's equation for when the pipe is full. However as a sewer utility, we're not allowed to fill pipes. We must keep...
Guest about 5 years ago in InfoWorks ICM / Grids / Reporting 2 Gathering support

Restrict user ability to "Empty Recycle Bin"

Ideally it would be good to give a couple of named users the ability to empty the recycle bin - everyone else can send things TO the recycle bin, and can go into the bin to recover 'deleted' items, but they won't be able to empty it. This function...
Jason Kulsdom over 3 years ago in InfoWorks ICM / Productivity 0 Gathering support

Customize the label size on image / schematics

Users want the ability to customize the label size that overlay on image/schematics so that they better visually align with the underlying image
Pete Mcintosh over 1 year ago in Info360 Insight / Images 0 In progress

Varying conduit/culvert shape along its length

When modelling irregular culverts, the shape of culvert usually varies along its length as well. EX: Culvert having 900mm dia at inlet, varies along its length and at outlet has 500mm. Can this be included in the options for transition of shape al...
Guest almost 2 years ago in InfoWorks ICM / River Modeling 1 Gathering support

Visibility by system type

It would be usefull to have the possibility to easily switch on and off the layers of different system types by ticking on and of the different types/layers in the Geoplan Layers and Themes. By using the themes and adding visibility it is possib...
Richard Wilbrink over 3 years ago in InfoWorks ICM / GIS Layers 3 Gathering support