Skip to Main Content
Autodesk
ADD A NEW IDEA

All ideas

Upstream and Downstream Trace Icons are misleading

Minor annoyance here and possible solution- can you change the icons for the upstream and downstream trace to actually be meaningful? at the moment both icons represent downstream and upstream trace at the same time and it doesn't make sense
Daniel Alexander about 1 year ago in InfoWorks WS Pro / Other 1 Gathering support

Export of foul network to Civils 3D

Currently, the InfoDrainage plugin requires the network to be analysed/validated before it can be imported, and this is not currently an option for the foul network and therefore prevents this type of network from being exported. After speaking to...
Henry Wilkinson 7 months ago in InfoDrainage / Civil3D Integration 1 Will not implement

Option to "remember my choice" on the Query Set Cache pop-up

The pop-up asking whether to use the cache or re-run Query Sets every time you switch scenarios can get annoying. It would be nice to have a checkbox that says "always re-run queries" or something to that effect so that this pop-up can be suppressed.
Grant Clemens 11 months ago in InfoWater Pro / Productivity 0 Gathering support

Comparison of total length of rehab methods vs total pipe length

Similar to 'Comparison of total length of defects vs total pipe length' however, rehab methods can be assigned to multiple defects. For example the rehab method 'lining' can be assigned to defect codes CC, CL, FM, etc. the total length of a rehab ...
Martha Nunez almost 2 years ago in Info360 Asset 1 Gathering support

Tools to clean up networks using the SWMM engine.

At the moment, the inference tools only work in a Wallingford network, and no tools are available in a SWMM network.
Guest 11 months ago in InfoWorks ICM / SWMM 3 Will not implement

Batch Multi Fire Flow

I want the ability to model many different cases of multi-fire flow in parallel. This is important because I have many areas that require fire flow that is greater than what a single hydrant and later can achieve. Performing this manually for each...
Nathan Gerdts 11 months ago in InfoWater Pro / Automation 0 Gathering support

Pump control based on tank head

Pump control based on tanks are currently set to tank level. I would like the option to set according to tank head as well. I currently set tank minimum and maximum levels at their "real" elevations so that the levels in pump control can match up ...
Chris Keil 8 months ago in InfoWater Pro / Productivity 1 For Review

Model results as TVD connectors

We'd like to have model results as an input in the TVD connectors. An example is where we have observed flows that we would like to use at a tributary and then switch to catchment flows when the observations run out. We know this can be done using...
Richard Body about 6 years ago in InfoWorks ICM / Calibration / Results / Sharing / Time Series DB 0 Gathering support

Customization of Grid Windows in InfoWorks ICM

Allow custom grid window layouts in InfoWorks ICM, much like the Property window. Allow the user to reorganize the columns, change the column widths, or hide unnecessary columns, and save it as a layout to be applied as a default.
Dave White almost 7 years ago in InfoWorks ICM / Grids 10 Already exists

Calculating and adding the Froude number to storm table output

Many municipalities and utilities want to maintain subcritical flow in the storm sewer system and avoid hydraulic jumps. The Froude number is used to establish subcritical vs. supercritical flow.
Guest almost 2 years ago in InfoDrainage / Reporting 2 For Review