Skip to Main Content
Autodesk
ADD A NEW IDEA

InfoWorks ICM

Showing 498 of 1170

Volume on a discharge graph with results section

When we display the graph of the discharge (flow through line) of a results section (line object), we don’t have access of the information about the volume (usually when we display a discharge graph, the volume is indicated at the bottom of the gr...
Guest over 2 years ago in InfoWorks ICM / Results / Visualization 0 Gathering support

Ability to snap to DWG or GIS background layers

When moving a manhole, I would like to snap to drawing geometry
Guest about 2 years ago in InfoWorks ICM / Productivity / Visualization 0 Gathering support

Better performance and functionalities of the recycle bin

In a workgroup database, the Recycle Bin today is more a nuisance than a useful feature. When there are too many items in it, it can delay the connection to the database considerably or even make it impossible to connect. The functionalities for s...
Guest almost 4 years ago in InfoWorks ICM / Productivity 1 Gathering support

Promote recently used flags

It would help if your recently used flags were promoted to the top of the flags list. For example, I am updating flags for some manhole surveys (flagged "SM"). Alphabetically, SM is close to the bottom of the list which means I have to scroll to...
Benjamin Mauck over 3 years ago in InfoWorks ICM / Flags 2 Gathering support

4K Screen

Not everything works well with 4K monitors (grips). Let's get real 4K workflow - not just a DPI scaling solution.
Matt Anderson 12 months ago in InfoWorks ICM / Productivity 0 Gathering support

Ground Models Management for combining

Provide a method to merge an existing ground model with a proposed condition model
Guest about 5 years ago in InfoWorks ICM / Mesh / Terrain 2 Gathering support

Add Vertex Workflow

The Edit Geometry Workflow for adding, and editting vertex is fragile. Inserting a vertex breaks the linear aspect of the 2D boundary as InfoWorks does not provide any feedback. Autodesk workflows in Civil 3D, InfraWorks, and Revit provide user fe...
Matt Anderson 12 months ago in InfoWorks ICM / Mesh 0 Gathering support

As a user I want to change the amount of decimals when applying Autolabels in Infoworks ICM

I want to change the amount of decimals when I apply Autolabels in Properties and Themes. Right now the default is three decimal places which I cannot edit.
Guest almost 3 years ago in InfoWorks ICM / Labels 1 Gathering support

Pump Station Modelling

Infoworks ICM pump station modelling principle is very basic, adding a pump between two nodes is highly hypothetical. There is no way to add pump station head losses. I would like to suggest incorporating pump station modelling (for Rotodynamic pu...
Guest over 2 years ago in InfoWorks ICM / Hydraulics / Pumps 1 Gathering support

Different shape sluice or pipe/orifice closure option

We usually model closed gates as sluices, as they are the ones that can easily be closed (by setting the height to zero). The downside of this is that it can only be a rectangle (and it usually closes off a round pipe). An orifice now has the nice...
Marcel Glasbergen over 1 year ago in InfoWorks ICM / Orifice / RTC 0 Gathering support