Showing 129 of 1370

inlet riser option for tank

Have an option to specify an Inlet Riser Pipe for the tank element. This would hold the fill head at a constant, set at the riser pipe elevation, but allow the tank discharge head vary with the tank level.
Guest almost 5 years ago in InfoWater Pro / Engine 0 Gathering support

Report InfoSWMM available capacity against theoretical flow for specified d/D

InfoSWMM provides Pipe/Conduit summary report with values for Max flow divided by "Full Flow". Here the "full flow" is based on Manning's equation for when the pipe is full. However as a sewer utility, we're not allowed to fill pipes. We must keep...
Guest about 5 years ago in InfoWorks ICM / Grids / Reporting 2 Gathering support

Add Alternative Demands to ICM

Add alternative demand feature (as exists in WSPro) so the impact of different growth (population) scenarios can be easily tested without having to create a new scenario and copy of the network for each iteration.
Alison Ormsby almost 2 years ago in InfoWorks ICM / Grids 2 Gathering support

Isolation Scenario Using Dummy Valves Which Do Not Split Pipes

Can you put a valve on top of a pipe (not splitting the pipe) and then it closes the section? And then anything enclosed to these multiple valves will be isolated? This is going to be useful for modelling of isolation scenarios
Guest almost 2 years ago in InfoWater Pro / Operational Modeling 3 Gathering support

Improvements to "Edit Attributes" table

The "Edit Attributes" window (accessed by using the "Edit Selection" or "Edit Domain" buttons) is a useful table to quickly view and edit all the physical information for each facility type together. However, it has some useability issues that som...
Colin Ricks almost 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Pasting Profile Names

While pasting grids with headers populates profile names - its not easy to accomplish when appending to the end of a table. One has to create a blank, and then tell the application to paste new profiles. This doesnt work from last profile. This wo...
Guest about 2 years ago in InfoWorks ICM / Grids 0 Gathering support

Hydrant and valve placement optimization

Hi there, We have been discussing the valve optimization in the whole County and if the InfoWater Pro can have the function to optimize the placements of hydrants and valves in the network to facilitate the design and high-level planning, that wou...
Guest about 2 years ago in InfoWater Pro / Productivity 1 Gathering support

Modify How InfoSurge Counts Features for Licensing

We have 20,000-pipe InfoSurge licenses. We frequently have operational models larger than that, where we want to perform Surge modeling. Even if we deactivate portions of the network, InfoSurge still counts the total number of features. This waste...
Guest almost 5 years ago in InfoWater Pro 1 Will not implement

New Feature is Active in All Scenarios Option (InfoWater/Pro)

Add a tools/options option so when you add new features they will be active in all scenarios, instead of getting errors 100 times for every scenario you try to run where the features were not included originally. This would be especially useful wh...
Guest almost 5 years ago in InfoWater Pro / Productivity 0 Gathering support

Account for multi-connection properties during criticality analysis

Some hospitals for example have multiple service laterals connecting them to the network. If one line is cut off from service due to a repair, the hospital can still get water. As a result, criticality is overestimated when this logic is ignored. ...
Nathan Gerdts over 2 years ago in InfoWater Pro / Other 0 Gathering support