Skip to Main Content
Autodesk
ADD A NEW IDEA

All ideas

Showing 1375 of 1375

Create an option in the Domain Manager to add elements by ID

The workflow to add a list of element IDs to the domain is too complicated. Simplify this by creating a new option in the Domain Manager, it could just open a table where you set the number of rows and paste IDs from a list/table copied from a pro...
Grant Clemens almost 2 years ago in InfoWater Pro / Productivity 2 Under consideration

"Show Maxima" Button

It would be great if there were a "show maximum" button like there is in InfoWorks ICM where you can see at what point in the simulation there is the most surcharge. this would save time trying to manually move the timeline to exactly where someth...
Midori Patterson almost 2 years ago in InfoDrainage / Productivity 1 Gathering support

Creating Demand scaling from the Demand Area Window

In 2024.5 it is possible to choose to 'ignore leakage' and to 'scale demands' when using the demand area analysis tool. The scaling is happening on the demand (consumption) in the network. This means I have to create a new network (or scenario) ev...
Caroline Heylen almost 2 years ago in InfoWorks WS Pro / Productivity 0 Gathering support

Python scripting API for ICM

Our team uses Python scripting extensively for data analysis and manipulation, while Ruby is foreign to us. Please provide scripting support for Python for model manipulation and analysis.
Guest over 5 years ago in InfoWorks ICM / API / Exchange 0 Gathering support

PIMP Classification

We have a option to input the type of Impervious area in MicroDrainage, can we carry that feature along with the choosing color code option to based on the PIMP.
Guest over 1 year ago in InfoDrainage / Other 1 In progress

Add (change template) inlet from template to a junction without erasing the part family for the existing object

For example, in a model exported from Civil 3D, HEC-22 inlets need to be added to 100s of structures. The workflow is: 1. Create an Object Template for the HEC-22 inlet2. Right click each structure and change template to add a HEC-22 inlet The pro...
Daniel'le DeVoss 12 months ago in InfoDrainage / Hydraulics 1 For Review

Pressure Relief Valve

Which valve, if any, would represent a pressure relief valve? Where the pressure on the upstream is not allowed to exceed a certain psi. If it exceeds the specified pressure on the upstream side the valve will open.
Guest 12 months ago in InfoWater Pro / Operational Modeling 2 For Review

Plan View Annotation - Choose no. decimal places on pipe gradient value etc.

Displaying pipe gradients on plan (from Display Settings), which can be exported to CAD, is a very useful feature. However, when displaying pipe gradients, in the form 1: X, the X value is shown to 2 decimal places by default. It would be really u...
Dara Magee 12 months ago in InfoDrainage / Visualization 0 For Review

Use PDM Soil moisture deficit variable to trigger RTC

Just like you can set thresholds or target values for level or flow in an RC I would like to be able to use the Soil moisture deficit variable from PDM subcatchment to regulate structures or variable pumps. This could be useful to somewhat reprodu...
Edith Maroy almost 3 years ago in InfoWorks ICM / Hydrology 0 Gathering support

Right click menu on objects to graph, trace, edit, etc. Similar to ICM

I want to interact with my model primarily from the map rather than relying on toolbars. Namely, I want to select an object and then access an action menu to graph, edit, trace, label, etc on that object. Note: ICM already supports this feature, s...
Nathan Gerdts 8 months ago in InfoWorks WS Pro / Productivity 0 For Review