Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 278 of 1370

Apply direct inflows to permeable paving

There should be a way of applying the inflow that the paving receives directly (i.e. the rain that falls onto it) to produce a more accurate simulation of the rainfall. This direct rainfall isn't a lateral or point inflow, and being forced to mode...
Craig Bobbett 10 months ago in InfoDrainage / Hydraulics 0 For Review

Exclude specific elements from Numbering Scheme (flow paths, manholes, simple junctions, etc).

Be able to have only manholes in the manhole schedule, without any missing manhole numbers. Junctions can be named separately and not included. Enable large sites with multiple areas to have their different areas named a different way easier.
Guest over 1 year ago in InfoDrainage / Auditing / Reviewing 2 Gathering support

Update downstream pipes

It would be useful to have an option to upsize downstream pipes automatically (just like microdrainage). For example, if i increase pipe size the corresponding downstream pipes should upsize accordingly so not to cause a restriction. At the minute...
Guest over 2 years ago in InfoDrainage / Productivity 2 Already exists

Extend flexibility in displaying information associated to HGL profiles

As an InfoWater user I'd like to be able to add more information to my HGL profile, including nodal pressure, pipe diameter, flow, velocity, etc. I'd like see max/min level achieved throughout the simulation and have the ability to quickly add pip...
Guest almost 6 years ago in InfoWater Pro / Productivity 2 Gathering support

Open Control Center on Selection, Selection Set, or Domain

For models with lots of controls, this would be helpful to quickly look a few at a time. For example, all the controls at a specific site. Right now, the list appears to be sorted randomly. It would also be helpful to automatically sort alphabetic...
Colin Ricks 10 months ago in InfoWater Pro / Productivity 0 Under consideration

Flow direction arrows default symbology

By default, flow direction arrows show up as blue for forward flow, red for backwards flow. This is a pointless distinction because for distribution systems, "forwards" or "backwards" depends on the direction the pipe was initially digitized and h...
Colin Ricks over 2 years ago in InfoWater Pro / Productivity 0 Under consideration

Allow underdrains to be displayed in the connection tables and add pipe number to them

It is very difficult to create a quick and logical pipe schedule when pipes such as underdrains are hidden in the SuDS nodes and their upstream invert level needs to be calculated manually. Please add the underdrains to the connection tables with ...
Iwona Savas 11 months ago in InfoDrainage 0 For Review

Infiltration Trench using BRE DIGEST 365 method

The software needs to support for designing Infiltration trench method by using “BRE DIGEST 365”. I have checked the comparison between Infodrainage analysis Vs BRE digest 365 (manual calculation) and the results are not matching. Most of the proj...
Guest almost 2 years ago in InfoDrainage / Hydraulics 8 Gathering support

Swale with pipe under connected by manholes

Could not model real-life scenario where the pipe was under as conveyance for lesser events and raised via vented manholes into the swale above. Need integrated solution and was unable to model both and connect via manholes.
Guest almost 2 years ago in InfoDrainage / Hydraulics 1 Already exists

Persistent Graphs in InfoWater/InfoWater Pro

Stored graphs aren't that great. Why not just make graphs persistent?
Guest almost 5 years ago in InfoWater Pro / Productivity 2 Under consideration