Showing 143 of 1370

Retain decimal places when copying/pasting grid values

For most numerical values in a model, ICM can hold 8 decimal places. From the grid view, if you copy/paste a single cell value, the full set of decimal values are preserved. However, if you copy multiple cell values at once (e.g. an entire column)...
Jason Kulsdom almost 3 years ago in InfoWorks ICM / Grids / Reporting 0 Gathering support

Enable Reference Graph type "Output from other sources" for Group Graphs

On a single element graph, you can use Reference Graph - Output from other output source(s) to compare results for that element from various scenario runs. This option should also be enabled for Group Graphs on multiple elements.
Grant Clemens almost 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Access to UDF Data through DB Editor

In InfoWater Pro, the model data can be accessed through the DB Editor. The UDF tool does not have any access to the database tables through the DB Editor. It would be very helpful if I could gain access to the UDF tables through the DB Editor, ev...
Matt Huang about 3 years ago in InfoWater Pro / Data Exchange 0 Under consideration

Batch Edit Datasets

Currently if there needs to be a global change to a dataset, the only way is to manually go through each dataset and change the element property and save. As an example, if a valve needs to be closed in multiple datasets, it would be nice to have ...
Joe Lawrence over 4 years ago in InfoWater Pro 0 Gathering support

improve print functionality

The print functionality in ICM could be improved very much (printing to PDF files). It takes at the moment a lot of time and even then it is not possible to easily (and flexible) fit a selection to the chose page setup (size) for example. Or fit a...
Richard Wilbrink over 2 years ago in InfoWorks ICM / Printing 1 Gathering support

Provide option to allow for several multipliers and use with selection sets

In addition to a global multiplier, sometimes you want to peak certain areas and selection sets with specific peaking factors. WaterCAD allows for this under their calculation options.
Michele Marston over 1 year ago in InfoWater Pro / Operational Modeling 0 Gathering support

modeling surge check valves

I’m also wondering if you all are considering adding more options on how to model check valves.
Guest about 2 years ago in InfoWater Pro / Engine 1 Gathering support

Closed surge tank initial water level

would be nice for the surge program, is to have the initial water level automatically calculated for closed surge tanks
Guest about 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Splitting pipe - surge wave speed not inherited

When splitting a pipe by inserting a node, the new pipe inherits the attributes of the original pipe (diameter, roughness, zone, material, etc). However, if the pipe has a wave speed assigned for surge modeling, the new pipe does not inherit the w...
Colin Ricks about 2 years ago in InfoWater Pro / Productivity 1 In progress

Use consistent terminology in the Fireflow Results Report

The Fireflow Results Report uses the following terms for what I believe are the same thing: Total Demand, Design Flow, & Fire Demand. If these are not the same in the context of this report then explain their differences. Also, the term "Hydra...
Guest 9 months ago in InfoWater Pro / Other 0 For Review