Japanese Standard Rainfall Intensity Formulas

In Japan, four rainfall intensity formulas (Talbot, Kuno-Ishiguro, Cleveland, Sherman) are used in sewerage planning, including stormwater drainage. According to a survey report by the Ministry of Land, Infrastructure, Transport, and Tourism, thes...
MASASHI KAWAMURA 5 months ago in InfoDrainage / Rainfall 0 Gathering support

Include pump HGL in simulation output

Standard output for InfoWater Pro includes hydraulic grade elevation for tanks and junctions. Since all pump design and performance information relates to hydraulic head (e.g., system curve, pump performance curve, etc.), in addition to (or in lie...
Michael Kane about 2 months ago in InfoWater Pro / Productivity 0 Gathering support

Continuous Matched Soffits or Inverts Snapping

It would be useful if all pipes in a junction automatically snapped to match either soffits or inverts. There is a variable in the Network Design Criteria for 'Level Soffits' or 'Level Inverts' so potentially this option could be used for the live...
Ian George 3 months ago in InfoDrainage / Productivity 0 Gathering support

Drag Labels in InfoDrainage Plan View

Text labels often end up overlapping and are illegible. It would be nice to be able to drag them like you can in CAD / Civil3D.
Midori Patterson about 2 years ago in InfoDrainage / Visualization 1 Gathering support

A way to toggle pumps on or off with a counter.

Under the rule-based control add a way to toggle pumps on/off when tanks cycle. For example, define the counter variable as N=0 initially, then when a tank completes one drain cycle N=1, 2nd drain cycle N=2, and your pump control would look to the...
Guest 2 months ago in InfoWater Pro / Other 2 Gathering support

Add Manhole 'clocks' to the manhole schedule

It would be useful to show a basic plan view of the manholes in the manhole schedules (with inlets and outlet alignments accurately shown). This is useful when contractors order per-cast manhole bases that require 'clock' diagrams.It would be real...
Ian George 3 months ago in InfoDrainage / Other 0 Gathering support

Foul Water Analysis

The ability to analyse foul water networks within Infodrainage is not fully supported. As we can build foul networks within Infodrainage, it would be helpful to output a set of calculations to demonstrate the suitability of the proposed network. C...
Morgan Harris 2 months ago in InfoDrainage / Hydraulics 0 Gathering support

Horizontal orifices as an outlet type

HydroCAD offers a horizontal orifice control outlet type that is very commonly used for detention pond outlet types in the US. Please include this as an outlet type so we can transition from HydroCAD to InfoDrainage.
Midori Patterson almost 2 years ago in InfoDrainage / Hydraulics 1 Gathering support

Import Civil 3D surface directly to Infodrainage

Importing a Civil 3D surface directly would eliminate any errors in the conversion process, ensuring triangulations are accurate and surface boundaries are observed
Guest 4 months ago in InfoDrainage / Civil3D Integration 0 Gathering support

Would it be possible to include longitudinal gradient (slope) to attenuation tanks please? At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet.

At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet (and this could then change the head of wate...
arek kadlec about 2 years ago in InfoDrainage / Hydraulics 1 Gathering support