Option to remove the additional storage automatically added in geocellular systems

When designing a cellular soakaway, infodrainage automatically assumes a 1m2 plan area chamber between tank soffit and exceedance level (which would have been specified as ground level). In other structures you can specify freeboard and exceedance...
Guest 4 months ago in InfoDrainage / Hydraulics 0 For Review

Better hydraulic representation of flow in permeable paving

Flow through permeable paving does not occur as one would expect. Is greatly affected by the shape and direction the paving is drawn in InfoDrainage. When drawing an irregular shape the hydraulic grade lines appear incorrect, with flow all at one ...
Guest 4 months ago in InfoDrainage / Hydraulics 0 For Review

Setting Out information for Swales

It seems I am unable to export proper 3D setting out data in the form of feature lines or 3D polylines for the base / top level of swales. I have designed several swales with a 1:200 gradient, but the export into C3D does not take into account the...
Guest 7 months ago in InfoDrainage / Civil3D Integration 0 For Review

TR-20 Runoff Generation

Can ID incorporate this methodology? MA department of Env Protection will be requiring this for their calculations.
Jess Ewing 12 months ago in InfoDrainage / Hydrology 1 Gathering support

Add Infiltration Option to Manholes

Other software allows you to add infiltration properties to manholes. In Western Australia, the use of Soakwells/Soakpits is an often practice and it is important to be able to account for this local infiltration within the Manhole
Hector Salgado 7 months ago in InfoDrainage / Hydraulics 1 Gathering support

Allow different Phases to use the same background files

When creating a new network through phasing we often wish to use the same CAD levels and background used by another network, without having to load another version of the same CAD files.
Guest over 1 year ago in InfoDrainage / Productivity 1 Will not implement

More Customizable Plot Plan view

Make the Plot Plan function more readable, it is difficult to get a whole design on one sheet especially with the header table in the way and not allowing for customization.
Jenna Woyner about 1 year ago in InfoDrainage / Visualization 1 Gathering support

Catchment area in different colour

currently the catchment area demarcation gives only a common colour at all area. we need to allow catchment area in different colors to demark Paved, unpaved, Road in details while we represent the details to client
Guest about 1 year ago in InfoDrainage / Visualization 1 Gathering support

Need more inlet options

SSA has numerous inlet manufacturers and jurisdictions, including Caltrans, FDOT, Neenah, etc. These would be beneficial to have in InfoDrainage, including East Jordan inlets. Additionally, have depth vs flow curve option would be helpful as well.
Guest 7 months ago in InfoDrainage / Hydraulics 0 For Review

Limit the chamber sizing calculator to 200 chambers

The chamber size calculator will add any number of chambers necessary, however, the model will not validate if the number of chambers exceeds 200. It would be better to not allow the calculator to exceed the validation limit.
Daniel'le DeVoss 5 months ago in InfoDrainage / Hydraulics 0 For Review