Outfall Details input window

The Outfall Details input window is of fixed size, in width and height. This makes using the "Level Curves" tab difficult, as in order to select a set of different hydrographs for different storm events, one must constantly scroll right and down t...
Nicholas Bond about 2 months ago in InfoDrainage / Productivity 0 Gathering support

Aerial background mapping

Would it be possible to add aerial background mapping, such as with AutoCAD.
Matthew Johnson over 1 year ago in InfoDrainage / Visualization 1 For Review

Relative file paths for CAD data etc.

Would it be possible to use relative file paths for attached information, such as CAD data. A lot of work is done on fileshare sites e.g. SharePoint. If one person syncs the model and another opens it, all the linked data is lost as the global fil...
Matthew Johnson over 1 year ago in InfoDrainage / Data Exchange 0 For Review

Infodrainage modeling and analysis in Civil 3D

It would be good at some point to be able to run Infodrainage hydraulic analysis directly in Civil 3D. See below key issues we currently have with export/import tool: Stormwater control features: For some reason, when exported to Civil 3D they a...
Guest 4 months ago in InfoDrainage / Civil3D Integration 0 Gathering support

Add max pipe flow to the pipe properties window

Max pipe flow (theoretical pipe full) is not listed in pipe properties, as it was previously in MicroDrainage. It was a useful feature.
Ian George 4 months ago in InfoDrainage / Productivity 0 For Review

Downstream pipes matching soffits/inverts

Currently when making changes in InfoDrainage the downstream pipes do not automatically adjust to the lowest incoming pipe. This means we have to manually adjust (and usually then lock) most pipes which is a downgrade from MicroDrainage.I understa...
Ian George 4 months ago in InfoDrainage 0 For Review

Provide Velocity Constraint in Multi-Fireflow

Provide the ability to limit velocity for the multi-fireflow run option. Presently only the Fireflow run option offers a max velocity constraint capability; the Multi-Fireflow run option does not have a max velocity feature.
Guest about 1 year ago in InfoWater Pro / Engine 0 In progress

Manhole Types

Please allow us to specify manhole types (DMRB, SSG etc.) and covers and ensure that this data is visible in the manhole schedule export
Guest about 2 years ago in InfoDrainage / Productivity 1 Gathering support

Chezy Formula option

It would be useful to have a direct input for Chezy coefficient as an alternative to mannings n as some regions need to use this as an input and report on this too - this would result in less workaround and data manipulation
matthew.piggott over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Provide InfoWater Pro integration with Civil 3D

Engineers and designers using Civil 3D for water distribution system design need to be able to verify the hydraulic adequacy of their designs quickly and efficiently in InfoWater Pro. There is currently no means by which to exchange Pressure Netwo...
Michael Kane about 2 years ago in InfoWater Pro / Data Exchange 2 Under consideration