Pump control based on tank head

Pump control based on tanks are currently set to tank level. I would like the option to set according to tank head as well. I currently set tank minimum and maximum levels at their "real" elevations so that the levels in pump control can match up ...
Chris Keil about 2 months ago in InfoWater Pro / Productivity 1 For Review

Allow more than 10 classes of Symbology in Map Themes

We have clients and models where there may be 15 to 20 different pipe sizes in their distribution system – It is extremely beneficial to be able to individually color-code and size-code them with symbology for easy reference. We used to be able to...
Guest about 2 months ago in InfoWater Pro / Other 3 In progress

Horizontal orifices as an outlet type

HydroCAD offers a horizontal orifice control outlet type that is very commonly used for detention pond outlet types in the US. Please include this as an outlet type so we can transition from HydroCAD to InfoDrainage.
Midori Patterson almost 2 years ago in InfoDrainage / Hydraulics 1 Gathering support

Improved catchment area import

Importing the catchment areas from cad is an extremely useful feature which would save hours of time, however, it does not work with all the areas and specifically not those with curved lines (most of the time). I think if infodrainage could impor...
Henry Wilkinson 7 months ago in InfoDrainage / Productivity 1 Under consideration

Import Civil 3D surface directly to Infodrainage

Importing a Civil 3D surface directly would eliminate any errors in the conversion process, ensuring triangulations are accurate and surface boundaries are observed
Guest 4 months ago in InfoDrainage / Civil3D Integration 0 Gathering support

Retaining CAD files / Orphaning

When CAD files are imported to InfoDrainage they retain the link to the CAD file, like a CAD Xref which is good. However if that file is moved, or InfoDrainage cannot access it, an error box is prompted and the entire CAD file is just deleted from...
Ian George 2 months ago in InfoDrainage / Productivity 1 In progress

Would it be possible to include longitudinal gradient (slope) to attenuation tanks please? At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet.

At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet (and this could then change the head of wate...
arek kadlec about 2 years ago in InfoDrainage / Hydraulics 1 Gathering support

Copy Stored Graphs with InfoWater Sync

Please add support for copying Stored Graphs between local and server copies of models with the InfoWater Sync tool. This is a very important tool for evaluating models and it would be very helpful to retain them when syncing between a server and ...
Guest 8 months ago in InfoWater Pro / Data Exchange 1 Under consideration

Add South African Standards and Rainfall data - using the information in the SA Civil country kit

This will enhance design accuracy and efficiency, meeting client requests. This ensures our designs align with the standards and the software.
Guest about 1 month ago in InfoDrainage 0 For Review

Freeboard in Results

When freeboard is exceeded from something like a basin, it is not immediately clear in the stormwater control results. It says flood risk and a water level that eats into the freeboard, but it does not flag up that this is an issue and is easily m...
Guest 10 months ago in InfoDrainage / Hydraulics 0 For Review