Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoWorks ICM

Showing 443

Calculation of Pump Power in ICM

A pump curve and energy/efficiency curve can be input into the software however there is no way to output the energy used by the pump. South Gippsland Water were keen on understanding whether ICM could do this to report their energy efficiency bas...
Ann Pugh about 5 years ago in InfoWorks ICM / Pumps 0 Gathering support

Scenario assigned 'official' ID numbers within software

I would like for scenario names to be prefixed with a built-in ID number, in the same way that model commits have official version numbers, and wastewater and trade waste profiles have ID numbers. ICM clearly tracks ID numbers behind the scenes, s...
Jason Kulsdom over 3 years ago in InfoWorks ICM / Scenario 1 Gathering support

Export both the result and the underlying property fields

When the model results are displayed on the webpage through Exchange, since the basic properties need to be viewed, the corresponding basic properties of the results need to be exported first, and then the results are matched to the basic properti...
Liu Qiusheng about 5 years ago in InfoWorks ICM / Export Data / Simulations 0 Gathering support

Active/Inactive Network Elements

Ability to activate and inactivate model elements in InfoWorks as one can do in InfoSWMM.
Michael Wetterau over 3 years ago in InfoWorks ICM / Productivity 0 Gathering support

Add Data Sets to InfoWorks

Add Data Sets to InfoWorks as one can do in InfoSWMM. Helpful when clients want to model alternatives scenarios and make last minute changes.
Michael Wetterau over 3 years ago in InfoWorks ICM / Productivity 0 Gathering support

Convergence Errors be resolved automatically while the model is simulated

Sometime a TSR running for few weeks throws up convergence hence these sims need to be rerun with shorter timestep which is both inefficient and a lot of time is wasted. It would be good if somehow the simulations dialog allowed to run the model w...
Salam Jamadar about 5 years ago in InfoWorks ICM / Performance / Simulations 0 Gathering support

Can the simulation log file be broken up into sections

Can the simulation log file be broken up into sections, as models get bigger and many with several 2d zone trying to find what is actual causing a simulations failure is becoming a bit more difficult having to scroll through big log files for that...
Bob Fleming over 5 years ago in InfoWorks ICM / Errors / Reporting 0 Gathering support

Allow Theming Inflow areas by attributes

I would like to visually theme the Inflow areas by an attribute, say, Percent Impervious (PIMP)
Guest over 3 years ago in InfoWorks ICM / Theme / Visualization 0 Gathering support

Option to pan through 2 or multiple geoplans at the same time

Sometimes (in ICM and IAM) in comparing 2 (or more) networks visually the networks are most of the time tiled horizontally of vertically. But when panning through one network, it would be very convenient that the other network(s) is/are also movin...
Guest over 5 years ago in InfoWorks ICM / Productivity 0 Gathering support

Report InfoSWMM available capacity against theoretical flow for specified d/D

InfoSWMM provides Pipe/Conduit summary report with values for Max flow divided by "Full Flow". Here the "full flow" is based on Manning's equation for when the pipe is full. However as a sewer utility, we're not allowed to fill pipes. We must keep...
Guest over 5 years ago in InfoWorks ICM / Grids / Reporting 2 Gathering support