Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 368 of 1442

A way to toggle pumps on or off with a counter.

Under the rule-based control add a way to toggle pumps on/off when tanks cycle. For example, define the counter variable as N=0 initially, then when a tank completes one drain cycle N=1, 2nd drain cycle N=2, and your pump control would look to the...
Guest 2 months ago in InfoWater Pro / Other 2 Gathering support

Add Manhole 'clocks' to the manhole schedule

It would be useful to show a basic plan view of the manholes in the manhole schedules (with inlets and outlet alignments accurately shown). This is useful when contractors order per-cast manhole bases that require 'clock' diagrams.It would be real...
Ian George 3 months ago in InfoDrainage / Other 0 Gathering support

Foul Water Analysis

The ability to analyse foul water networks within Infodrainage is not fully supported. As we can build foul networks within Infodrainage, it would be helpful to output a set of calculations to demonstrate the suitability of the proposed network. C...
Morgan Harris 2 months ago in InfoDrainage / Hydraulics 0 Gathering support

Run Network Review Fix on portion of model

I would like to run the Network Review Fix tools on a portion of a model. Currently most tools are run on the entire model and then a domain is created on potential items to fix. If i am adding newly installed water mains into an existing model it...
Chris Keil about 2 months ago in InfoWater Pro / Productivity 0 For Review

Addition of infiltration flows to foul drainage models in subcatchment items

When designing foul pipe networks, client guidance often directs users to incorporate an allowance for infiltration into pipes from the surrounding ground water. This is applied in addition to foul flows currently defined using the Main Drainage/ ...
Michael McWhinnie 7 months ago in InfoDrainage / Hydraulics 0 For Review

Export of foul network to Civils 3D

Currently, the InfoDrainage plugin requires the network to be analysed/validated before it can be imported, and this is not currently an option for the foul network and therefore prevents this type of network from being exported. After speaking to...
Henry Wilkinson about 1 month ago in InfoDrainage / Civil3D Integration 1 Will not implement

Import Civil 3D Parts Lists to InfoDrainage

Currently, we can create parts lists in InfoDrainage and save them for reuse. However, it would be ideal if parts lists from Civil 3D could be imported directly into InfoDrainage.
Daniel'le DeVoss 8 months ago in InfoDrainage / Civil3D Integration 0 For Review

Attenuation Volume Summary Analysis

It would be useful to have access to a table that summarises all the attenuation volumes within the site include elements such as tanks, filter trenches, pipes, manholes etc. Similar to what was available in MicroDrainage
Guest over 1 year ago in InfoDrainage / Auditing / Reviewing 2 In progress

Add check dams as a feature for swales

Add a check dam setting with height, notch weir and interval settings to simplify modelling swales on sloping sites. This avoids having to model several sections of swale in order to use the available storage.
Oliver Dodd over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Pressure-based Thiessen polygon coloring in Map Themes

I want to see the spatial distribution of service pressures throughout my city with dynamic map themes that stay up to date with model results.Idea: Add an option in Map Themes to color-code thiessen polygons around each Junction based available o...
Nathan Gerdts 25 days ago in InfoWater Pro / Other 0 For Review