Better hydraulic representation of flow in permeable paving

Flow through permeable paving does not occur as one would expect. Is greatly affected by the shape and direction the paving is drawn in InfoDrainage. When drawing an irregular shape the hydraulic grade lines appear incorrect, with flow all at one ...
Guest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Simulation Health Improvements

In certain instances, the suggestions provided in "Simulation Health: The results indicate flow continuity issues, even when the shortest time step is already selected in InfoDrainage" may not resolve the problem. This could be addressed by incorp...
Guest over 1 year ago in InfoDrainage / Hydraulics 1 In progress

Add SuDS Planner tool to InfoDrainage

It would be good if we have the "SuDS Planner" tool available inside InfoDrainage similar to the one we have in MicroDrainage-Source Control module
Dilraj KT over 2 years ago in InfoDrainage / Other 3 Gathering support

Add Gravel Pit to Soakaway Design Tool

As a former MicroDrainage user, I'm struggling to model soakaways in InfoDrainage, as InfoDrainage does not account for storage volume within the gravel filter media that surrounds the soakaway. The gravel pit also provides larger area of infiltra...
Aleks Persins over 1 year ago in InfoDrainage / Hydraulics 5 Already exists

Variable baseflow

(Could also be considered hydraulics) On large scale projects where we may have limited information and funding, we assume baseflow values through an upstream point inflow. It would be beneficial to have a variable baseflow input per design storm....
Jess Ewing almost 2 years ago in InfoDrainage / Hydrology 1 Gathering support

Add the ability to duplicate connections between phases

Currently it is possible to duplicate stand-alone objects to different phases. Connections are not included in this. To duplicate connections to a different phase, the engineer must export the connections to a different format then re-import those...
Guest about 1 year ago in InfoDrainage / Productivity 1 Gathering support

Schematic for Dry Wells

When adding a dry well, it would be useful to provide some labelled images like those available for other stormwater controls to clarify what the properties are refering to.
Midori Patterson almost 2 years ago in InfoDrainage / Visualization 1 Gathering support

Limit the chamber sizing calculator to 200 chambers

The chamber size calculator will add any number of chambers necessary, however, the model will not validate if the number of chambers exceeds 200. It would be better to not allow the calculator to exceed the validation limit.
Daniel'le DeVoss about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Adding a "Default" selection box when Outputting information

To ensure the information output is not too much or too little, it would be good to have a default set of information that can assist LLFAs in reviewing print outs. This came up during a webinar I attended about auditing models. Sometimes you can ...
Guest about 1 year ago in InfoDrainage / Auditing / Reviewing 0 For Review

Increase the limit of Chambers allowed

Currently in the 2025.2 version I am running, the number of Chambers for subsurface storage/detention allowed is 200. The sizing calculator says I need more and wouldn't validate the model. Would be nice to have a higher limit.
Bryan Forrest about 1 year ago in InfoDrainage / Hydraulics 0 For Review