Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 138 of 1442

Totalizer Valve and Controls

It would be very useful to have a totalizer valve which closes after a certain amount of flow passes through over a given time, such as 5 MGD over a day, then reopens once that time period has passed. Alternatively, a control option based on a pip...
Guest over 1 year ago in InfoWater Pro / Operational Modeling 2 Under consideration

Make Scenario Explorer window panes resizable to see long Data Set names

When you resize the Scenario Explorer window, the left side with the Scenarios gets larger but the right side with Data Set / Facility / General tabs does not widen, so you can't see long Data Set names without opening a separate window.
Grant Clemens over 1 year ago in InfoWater Pro / Productivity 0 Gathering support

Add an option to automatically Refresh All graphs in the Report Manager after a new run.

Currently when you complete a new run you have to remember to hit Refresh All in the Report Manager to see latest results. The use-case for viewing old run results is rare, so having an option to automatically refresh all graphs and tables would b...
Grant Clemens almost 2 years ago in InfoWater Pro / Productivity 0 Gathering support

InfoSurge constant reporting interval

Often, different InfoSurge runs report results at different intervals, even though the simulation duration is the same. This makes it difficult to do comparisons of results. Please allow the user to set a report timestep like you can with a standa...
Colin Ricks 7 months ago in InfoWater Pro / Productivity 0 For Review

Default tank symbol

Can you change the default tank symbol color back to the dark blue that it used to be? The teal color is very light, making it difficult to see and hard to differentiate from the reservoir symbol. I know I can change this in preferences, but it wo...
Colin Ricks about 1 year ago in InfoWater Pro / Productivity 0 In progress

Option to relate split pipe ID to original ID

When splitting pipes, the new ID for the resulting pipe is based on the ID and Description tab in the model's Preferences. Instead of going with those settings, it would be nice to have an option to enable that would instead take the original ID a...
Kim Solberg almost 2 years ago in InfoWater Pro / Other / Productivity 0 Gathering support

InfoSurge velocity results

Please add pipeline velocities to the results for surge simulations. This really helps when designing surge tanks and connecting pipelines.
Guest 12 months ago in InfoWater Pro / Engine 1 Gathering support

Add support to the GIS Layer Control to access the new OS Open Data API's WMTS

Enhance/Add support to the GIS Layer Control to access the new OS Open Data API's WMTS. It appears at the minute you can only add WMS layers. https://osdatahub.os.uk/
Guest over 5 years ago in InfoWorks ICM / API / Exchange / Data Exchange / GIS Layers / Import data 1 Gathering support

Option to Import dfs0 format depth (level), velocity, flow and rainfall files into ICM

Right now, New Zealand region is using Mike Urban and Mike + suites for wastewater/stormwater networks modelling. Also, the water companies and councils are moving towards InfoWorks ICM. We have import tool for models from Mouse to ICM (with some ...
Guest over 2 years ago in InfoWorks ICM / Import data 1 Gathering support

Steady state simulations for different times or for average demand

Steady state simulations are useful for 1) evaluating an initial or simplified version of a model (for example with average demands) or 2) evaluating a specific condition (like maximum demand, etc.) without much complexity. If your model is alread...
Felipe Hernandez 8 months ago in InfoWater Pro / Engine 0 Gathering support