Showing 163 of 1370

Option to remove the additional storage automatically added in geocellular systems

When designing a cellular soakaway, infodrainage automatically assumes a 1m2 plan area chamber between tank soffit and exceedance level (which would have been specified as ground level). In other structures you can specify freeboard and exceedance...
Guest about 1 year ago in InfoDrainage / Hydraulics 3 For Review

Permeable Pavement with varying depth

Please add an option to input the surface slope and formation level slope for the permeable pavements to represent the varying depth of storage below. This is one of the 3 options we use at steeper sites to provide adequate storage in permeable pa...
Dilraj KT over 1 year ago in InfoDrainage / Hydraulics 0 For Review

HEC-22 Inlet reporting

The "Export HEC-22 Result to Excel" button in the calculator only includes results. Looking at flexible reporting, the HEC-22 data is only input, so I then have to use the results data from the calculator and the input data from flexible reporting...
Guest 8 months ago in InfoDrainage / Hydraulics 1 For Review

Weir coefficients

Expand the allowable range of weir discharge coefficients in InfoDrainage and provide an optional depth–coefficient user defined table to improve modeling flexibility and accuracy. Weir discharge coefficients (English units) typically range betwee...
Guest 4 months ago in InfoDrainage / Hydraulics 0 For Review

Liquid filled/Flooded drainage network

Liquid filled/Flooded drainage network- the system should be required to design flooded drainage network i.e. drainage pipe should be always filled with liquid for entire length up to the discharge point. Like a surcharge up to manhole cover (liqu...
Guest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

VSP Control based on Tank Head/Level

Currently you can only use Junction Pressure setpoints or Pump Flow setpoints in the VSP Control dialogue. It would be helpful to be able to use a Tank Level/Head setpoint to adjust the pump speed as well. This is possible in competitor products l...
Grant Clemens over 2 years ago in InfoWater Pro / Operational Modeling 3 Under consideration

Button: Apply to all phases

To each of the build screens, next to "apply", add another button, "apply to all phases". This would save a lot of time when making tweaks to models for which more than one phase is being run (which is most models)
Guest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Steady state simulations for different times or for average demand

Steady state simulations are useful for 1) evaluating an initial or simplified version of a model (for example with average demands) or 2) evaluating a specific condition (like maximum demand, etc.) without much complexity. If your model is alread...
Felipe Hernandez 4 months ago in InfoWater Pro / Engine 0 Gathering support

Please add an Innovyze section to the autodesk forums

Hello, Innovyze previously had a forum available for their products. After the software was purchased by autodesk, this no longer seems to exist. I believe having a forum where users can post questions and troubleshoot their issues would be very h...
Endrit Shabani almost 2 years ago in InfoWater Pro / Other 2 Gathering support

Level Soffits in pipe network.

Although you can select Level Soffits in the Network Wizard, if you make a change in the manhole depth for example, the pipes in the network will return to invert level, which means that you will have to readjust them manually.
Konstantinos Koutroulis almost 2 years ago in InfoDrainage / Hydraulics 1 In progress