Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 1067 of 1442

Option to "remember my choice" on the Query Set Cache pop-up

The pop-up asking whether to use the cache or re-run Query Sets every time you switch scenarios can get annoying. It would be nice to have a checkbox that says "always re-run queries" or something to that effect so that this pop-up can be suppressed.
Grant Clemens 5 months ago in InfoWater Pro / Productivity 0 Gathering support

Themes to include robust SQLs

Can we enhance conduit theming using robust SQL queries? We're aiming to apply themes based on the mean of minimum upstream and downstream velocities in each conduit over the TSR simulation. Considering the multiple scenarios involved in system de...
Parameswara Rao Narra 9 months ago in InfoWorks ICM / Theme 4 Already exists

worst case Grid report to include min values

Can the worst case grid report be enhanced to include minimum values for velocity and flow, similar to how it currently reports maximum upstream and downstream flow? This addition would be highly beneficial for understanding hydraulic behavior dur...
Parameswara Rao Narra 9 months ago in InfoWorks ICM / Results 3 Already exists

Support for more than two simulations in long sections

When evaluating the effects of raising and lowering roughness it would be helpful to display three or more simulations in the same long section; at the moment it is only possible to display 2.
Richard Body over 6 years ago in InfoWorks ICM / Long Section / Profile / Productivity / Results 0 Gathering support

Partially complete a simulation and review results and then opt to continue the simulation

Simulations often take a long time to run. I would like to be able to "pause" the simulation and review the results to check that the initialisation is correct, or that an RTC is working properly, and if I am happy then continue the simulation to ...
Ann Pugh over 6 years ago in InfoWorks ICM / Productivity / Reporting / Results / Simulations 2 Under consideration

Tools to clean up networks using the SWMM engine.

At the moment, the inference tools only work in a Wallingford network, and no tools are available in a SWMM network.
Guest 5 months ago in InfoWorks ICM / SWMM 3 Will not implement

Easily transform node from one type to another

Self explanatory. Use a user selection or domain.
Colin Ricks about 1 year ago in InfoWater Pro / Productivity 1 Under consideration

SCS generation - automatically pull data

InfoDrainage says it 'Generate(s) SCS data' but it really just links to the SCS website. Can Autodesk refine this to be more like the NOAA Atlas 14 which really does pull the data automatically into InfoDrainage.
Tim Medearis 11 months ago in InfoDrainage / Rainfall 0 For Review

Not able to drag and open duration window in Infodrainage 2026

Not able to drag and open duration window in Infodrainage 2026
Guest about 2 months ago in InfoDrainage / Rainfall 3 Will not implement

Adding 'Fall' of connections to tables and make editable

in the editing table we only have slope, and invert levels to edit connections. It would be greatly useful if the fall was added to a the pipe data table so this can be viewed and edited where. particularly for maintaining level soffits and check ...
Guest 7 months ago in InfoDrainage 0 For Review