Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 278 of 1370

Pump and Valve symbol that indicates direction

The default symbols for Pumps and Valves should ideally indicate the direction they're pointing. This should involve dynamic symbol rotation based on connected pipes (not results). That way I can visually validate my data before running the model....
Nathan Gerdts about 2 months ago in InfoWater Pro / Productivity 0 Under consideration

Repeat Table Headers on each page

The report tables currently display the table headers once under each return period / critical event. If the headers were repeated on each page, the tables would be easier to read. Thanks
Guest 6 months ago in InfoDrainage / Reporting 1 Gathering support

Ability to move labels to avoid overlaps

At the moment if labels overlap the only way to read the information on screen is to reduce all text size, which has other readability issues.
Matthew Johnson about 1 year ago in InfoDrainage / Visualization 0 For Review

Would it be possible to include longitudinal gradient (slope) to attenuation tanks please? At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet.

At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet (and this could then change the head of wate...
arek kadlec over 1 year ago in InfoDrainage / Hydraulics 1 Gathering support

Set gradient and/or pipe size of multiple parts within a single flow path in one operation.

In some instances we need to change the gradient or pipe size of an entire flow path. It would be helpful if this could be done in one operation rather than each part individually. Any branch connections could also update to align unless locked.
Guest about 1 year ago in InfoDrainage / Productivity 1 For Review

Pipe Properties Table

It would be really nice to add a pipe properties management table to help manage roughness factors and wave speeds. This is a feature in KyPipe: Surge and it is extremely helpful when assigning wave speeds to pipelines. The table classifies pipe t...
Guest 4 months ago in InfoWater Pro / Productivity 1 Gathering support

Add ability to see all pipes in Network Design Report

It is not possible to view the details / preliminary results of all the connections in the Network Design Report (each flow path needs to be selected in turn). This can be awkward for large networks.
Matthew Johnson about 1 year ago in InfoDrainage / Auditing / Reviewing 0 For Review

Provide a "Remove elements from domain" option within DB Editor, Edit Domain Attributes, and tabular results report

I would like to be able to remove items from the domain as I review them within DB Editor, Edit Domain Attributes, and tabular results report tables, similar to the "Append to Domain" available when "right clicking" on an item in DB Editor.
Guest about 1 month ago in InfoWater Pro / Productivity 0 For Review

Add check dams as a feature for swales

Add a check dam setting with height, notch weir and interval settings to simplify modelling swales on sloping sites. This avoids having to model several sections of swale in order to use the available storage.
Oliver Dodd about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Parcel Import to Catchment

It would be extremely helpful if InfoDrainage could import Civil 3D Parcels directly as catchment areas, similar to how it currently imports other CAD data (polylines). Parcels often represent drainage catchments, lots, or contributing areas in si...
Guest 2 months ago in InfoDrainage / Data Exchange 0 For Review