Showing 22

Copy Stored Graphs with InfoWater Sync

Please add support for copying Stored Graphs between local and server copies of models with the InfoWater Sync tool. This is a very important tool for evaluating models and it would be very helpful to retain them when syncing between a server and ...
Guest 5 months ago in InfoWater Pro / Data Exchange 1 Under consideration

Pump and Valve symbol that indicates direction

The default symbols for Pumps and Valves should ideally indicate the direction they're pointing. This should involve dynamic symbol rotation based on connected pipes (not results). That way I can visually validate my data before running the model....
Nathan Gerdts 3 months ago in InfoWater Pro / Productivity 0 Under consideration

Easily transform node from one type to another

Self explanatory. Use a user selection or domain.
Colin Ricks 12 months ago in InfoWater Pro / Productivity 1 Under consideration

Provide Velocity Constraint in Multi-Fireflow

Provide the ability to limit velocity for the multi-fireflow run option. Presently only the Fireflow run option offers a max velocity constraint capability; the Multi-Fireflow run option does not have a max velocity feature.
Guest 12 months ago in InfoWater Pro / Engine 0 Under consideration

Provide InfoWater Pro integration with Civil 3D

Engineers and designers using Civil 3D for water distribution system design need to be able to verify the hydraulic adequacy of their designs quickly and efficiently in InfoWater Pro. There is currently no means by which to exchange Pressure Netwo...
Michael Kane almost 2 years ago in InfoWater Pro / Data Exchange 1 Under consideration

VSP Control based on Tank Head/Level

Currently you can only use Junction Pressure setpoints or Pump Flow setpoints in the VSP Control dialogue. It would be helpful to be able to use a Tank Level/Head setpoint to adjust the pump speed as well. This is possible in competitor products l...
Grant Clemens over 2 years ago in InfoWater Pro / Operational Modeling 3 Under consideration

Totalizer Valve and Controls

It would be very useful to have a totalizer valve which closes after a certain amount of flow passes through over a given time, such as 5 MGD over a day, then reopens once that time period has passed. Alternatively, a control option based on a pip...
Guest about 1 year ago in InfoWater Pro / Operational Modeling 1 Under consideration

Default tank symbol

Can you change the default tank symbol color back to the dark blue that it used to be? The teal color is very light, making it difficult to see and hard to differentiate from the reservoir symbol. I know I can change this in preferences, but it wo...
Colin Ricks 12 months ago in InfoWater Pro / Productivity 0 Under consideration

Create an option in the Domain Manager to add elements by ID

The workflow to add a list of element IDs to the domain is too complicated. Simplify this by creating a new option in the Domain Manager, it could just open a table where you set the number of rows and paste IDs from a list/table copied from a pro...
Grant Clemens almost 2 years ago in InfoWater Pro / Productivity 2 Under consideration

Access to UDF Data through DB Editor

In InfoWater Pro, the model data can be accessed through the DB Editor. The UDF tool does not have any access to the database tables through the DB Editor. It would be very helpful if I could gain access to the UDF tables through the DB Editor, ev...
Matt Huang about 3 years ago in InfoWater Pro / Data Exchange 0 Under consideration