Ground Model Export utilizing Zones

allow existing zones to be used to restrict extent of ground model imports and Exports
Richard Robinson over 2 years ago in InfoWorks ICM / Export Data 0 Gathering support

Automatic WO or Inspection Generation based on a risk threshold or CCTV data import

Making risk real time and tying it closer to actions which actually occur out in the field makes our software stickier.
Tim Medearis almost 5 years ago in Info360 Asset / Work Management 0 Gathering support

Allow Users to have access to the Admin page and Edit Theme capabilities

Many users won't have the Admin permissions under the manage.autodesk.com page so this will allow any users to edit tenant settings such as units, coordinate system, etc. In addition to theme editing.
Martha Nunez over 2 years ago in Info360 Asset / Data Management 0 Gathering support

New Feature is Active in All Scenarios Option (InfoWater/Pro)

Add a tools/options option so when you add new features they will be active in all scenarios, instead of getting errors 100 times for every scenario you try to run where the features were not included originally. This would be especially useful wh...
Guest almost 5 years ago in InfoWater Pro / Productivity 0 Gathering support

Restrict use of a simulation server to specific users - to give priority to certain workflows

In a workgroup setting with ICM with several simulation servers it is possible to limit a named group of simulation servers (a "group" can be just one server) for use with specific ICM model databases. We would like to be able to limit use of a s...
andy.bolden almost 5 years ago in InfoWorks ICM / Simulations 0 Gathering support

Run SQL Query across multiple simulation results

Similar to how ICM lets me run a SQL query across multiple networks, I want to use SQL to summarize results in a custom way across multiple simulation results objects. Ideally they could be joined in one table similar to the way one can query fro...
Guest almost 5 years ago in InfoWorks ICM / SQL 1 Gathering support

Enable alternate versions of the SWMM engine within ICM

I would like to have the option to use a different version of the SWMM engine to be run instead of the latest Innovyze version. In some cases this is required, but it is often very helpful to confirm the results from previous versions.
Guest almost 5 years ago in InfoWorks ICM / Simulations / SWMM 2 Gathering support

Account for multi-connection properties during criticality analysis

Some hospitals for example have multiple service laterals connecting them to the network. If one line is cut off from service due to a repair, the hospital can still get water. As a result, criticality is overestimated when this logic is ignored. ...
Nathan Gerdts over 2 years ago in InfoWater Pro / Other 0 Gathering support

Apply two-valve isolation for criticality analysis

For some projects we need to isolate the repair area with two closed valves in all directions in case one valve were to fail. Please incorporate this as an option in criticality analysis when summing affected customers
Nathan Gerdts over 2 years ago in InfoWater Pro / Other 0 Gathering support

As a user of InfoWorks WS PRO, I would like to better simulate FMV valves

In InfoWorks WS PRO is possible to simulate FMV valves, but I would like to introduce a "deviation" option to better simulate it. I give an example: imagine a valve whose pressure setting is 2 Bar if flow is from 0 to 10 L/s, and 2.5 Bar if flow i...
Paolo Boiardi over 2 years ago in InfoWorks WS Pro / Engine 0 Gathering support