Add Date Properties to Scenario Objects (Ruby)

This would add a `date_created` or `date_last_committed` field to Scenario Objects in the `WSApplication.current_network`. It could be used to delete (or archive) old scenarios. For example, this would allow users to write a ruby script that can...
Craig Jones over 4 years ago in InfoWorks ICM / API / Exchange 0 Gathering support

Get the elapsed time of the simulation in ICM Exchange

It is not possible to get the information of the Job Control window with the current ICM Exchange, but it would be very useful to be able to create a dashboard using ICM Exchange to manage simulations and coordinators.
Guest over 4 years ago in InfoWorks ICM / API / Exchange 0 Gathering support

Change coordinate system of a model more easily

We have a large project running for several years and our design team is working in one coordinate frame. Our clients models are all in another coordinate frame. Our team would like to reproject the models into the design coordinate frame but ther...
Guest over 4 years ago in InfoWorks ICM / GIS Layers 0 Gathering support

Reintroduce ICM 11 searching for a viewer licence if a full licence isn't available

We use ICM version 7, 9 and 11 as per client requirements. We have 2 full licences and 2 viewer licences. When the full licences were already in use, ICM version 7 and 9 would automatically open with a viewer licence. This doesn't happen anymore w...
Tom Newman over 4 years ago in InfoWorks ICM / Other 0 Gathering support

Allow the InfoWater Pro "Live Data Adapter" to use non-live data

The Live Data Adapter can be a powerful tool for calibrating models, but is difficult to set up. Many times, you don't have permission to connect to the SCADA historian database. Right now, it only supports ClearSCADA, PI, SQL Server, and Oracle, ...
Colin Ricks over 4 years ago in InfoWater Pro 0 Gathering support

Display Warnings when Tank Stage/Volume Curve Inconsistent with Levels

As far as I can tell this is an EPANET bug, but say your tank levels are set to minimum 4 and maximum 20. If you have a stage/volume curve that goes below 4, your tank will supply water forever from a level of 4 feet.
Guest almost 5 years ago in InfoWater Pro 1 Already exists

Bring back the pause button for calculation.

In one of the first version of Infoworks there was a pause button for calculation. We have some big calculations who mostly run at nighttime. Sometimes the run is so big it still runs in the morning. The only thing we can do is stop the calculatio...
Erik Amting almost 5 years ago in InfoWater Pro 0 Will not implement

I want to be able to customize the minor loss table for pipe networks.

It would be nice if the user could modify the minor loss table for pipes. Whether it be changing the minor loss values, deleting, or editing the existing values. Since we all have our own resource we typical reference for these values, it would be...
Guest almost 5 years ago in InfoWater Pro 1 Gathering support

Allocate a subcatchment’s flows among several nodes

This is an idea from CDM Smith == I have an engine feature idea that has occurred to me at various times but never acted on. Today I was discussing an InfoWorks model with a junior colleague. It would clearly help us in this model to be able to al...
Guest almost 5 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

CAM Enhancement

CAM Enhancements A few things to consider that I think would make your tool better than others I have seen/used: 1. The ability to export the pounded areas into GIS. It seems to me this shouldn’t be difficult as you are color coding them now in ...