Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoWater Pro

Showing 60

Apply two-valve isolation for criticality analysis

For some projects we need to isolate the repair area with two closed valves in all directions in case one valve were to fail. Please incorporate this as an option in criticality analysis when summing affected customers
Nathan Gerdts over 2 years ago in InfoWater Pro / Other 0 Gathering support

I would like more informative error messages when trying to Change an ID

I tried to change the ID for a pump, but I overlooked the “Target Element Type” dropdown, which was automatically set to junction. It took me a while to realize my mistake. It might be helpful to other users if the error messages/warnings (see be...
Guest over 5 years ago in InfoWater Pro / Productivity 0 Gathering support

Automatically autofit DB table column widths

No description provided
Colin Ricks about 6 years ago in InfoWater Pro / Productivity 1 Gathering support

Automate concurrent Fireflow simulations

When you integrate InfoWater into the InfoWorks platform, it would be great if you could ensure that FireFlow simulations can be scheduled and automatically run sequentially for different network scenarios. As far as I am aware this is not possibl...
Guest about 6 years ago in InfoWater Pro / Engine 0 Gathering support

For fire flow simulations, I would like to have range reports for pipes, valves, pumps, reservoirs, and tanks.

For example, I would like to know the maximum, minimum, and average velocity through each PRV across all fire flow runs in a simulation.
Guest over 6 years ago in InfoWater Pro 0 Gathering support

Default Symbol and Map Display

Please allow the option to choose the default symbol (InfoWater Model Preferences) and Map Display symbol from the "Styles" built into ArcGIS Pro. Both ESRI and my company have custom .stylx files that house our custom symbols for points, polyline...
Joe Lawrence over 4 years ago in InfoWater Pro 1 Gathering support

Allow the InfoWater Pro "Live Data Adapter" to use non-live data

The Live Data Adapter can be a powerful tool for calibrating models, but is difficult to set up. Many times, you don't have permission to connect to the SCADA historian database. Right now, it only supports ClearSCADA, PI, SQL Server, and Oracle, ...
Colin Ricks almost 5 years ago in InfoWater Pro 0 Gathering support

I want to be able to customize the minor loss table for pipe networks.

It would be nice if the user could modify the minor loss table for pipes. Whether it be changing the minor loss values, deleting, or editing the existing values. Since we all have our own resource we typical reference for these values, it would be...
Guest about 5 years ago in InfoWater Pro 1 Gathering support

Customize pipe ID field in UDF field journal

Currently the model ID's are populated in the "Pipes to Flush" box of the UDF field journal. We store our GIS Asset ID in an information field. We want to use this field as the basis of communication with field teams.
Guest about 5 years ago in InfoWater Pro / Operational Modeling 0 Gathering support

Smarter UDF Flush Sequence Manager Operations tab selection tools

When using the UDF Flush Sequence Manager Operations tab [Close >], [Open >], or [Remove >] selection tools, I would like to receive the error "WARNING: Node ### is not in the Selection Set 'VALVES'" less often. Currently you must zoom ...
Guest over 5 years ago in InfoWater Pro / Productivity 0 Gathering support